“REC”: The signal is output during recording.

“PLAY”: The signal is output during playback.

“POWER”:The signal is output when the unit’s power switch is on.

“REMAIN”: The signal is output when the remaining stor- age capacity of main HDD, archive device reaches the rate which is set in CAPACITY REMAIN.

5.Turn the SHUTTLE ring to the left or press the SET UP button.

Capacity remain setting

When MODE OUT is set to “REMAIN” and the remaining stor- age capacity of main HDD or archive device is running out, this unit gives a warning. The following shows how to set the device and its remaining capacity ratio to give warning.

When the remaining storage capacity reaches the assigned % remain during recording:

The display of the recorded storage capacity flashes when “DISPLAY MODE 3” is selected.

The buzzer sounds when BUZZER in the <REAR TERMINAL> menu is set to “REMAIN”.

Example: Setting CAPACITY REMAIN to “HDD-50%” (the default setting is “HDD-10%”).

1.Display the <MENU SETTING> menu and turn the JOG dial until the cursor is next to “REAR TERMINAL”.

DATA CLEAR SELECTION￿ COMMUNICATION SETTING￿

@REAR TERMINAL￿ SERVICE

2.Turn the SHUTTLE ring to the right to show the <REAR TERMINAL> menu.

3.Turn the JOG dial until the cursor is next to “CAPACITY REMAIN” and turn the SHUTTLE ring to flash the sub-item.

The sub-item of the device will start flashing first. Choose the device you want to set by using the JOG dial and SHUTTLE ring. Then sub-item of the remain will start flashing.

<REAR

TERMINAL>￿

MODE

OUT

PLAY￿

@CAPACITY

REMAIN HDD-10%

 

 

 

4.Turn the SHUTTLE ring and JOG dial to show “HDD-50%” and turn the SHUTTLE ring to the right to complete setting.

By turning the JOG dial, the sub- item of CAPACITY REMAIN shown on the menu will be changed as follows:

HDD ARC NONE

By turning the JOG dial, the sub- item of CAPACITY REMAIN shown on the menu will

be changed as follows:

10% 15% 20% 30%40%

8% 6% 4% 2% 50%

5.Turn the SHUTTLE ring to the left or press the SET UP button.

CALL OUT setting

With this setting, the signal from CALL OUT terminal is emit- ted externally to indicate a warning.The signal is emitted from the CALL OUT terminal when the remaining storage capacity reaches the preset amount. Likewise, the remaining storage capacity of archive medium can be set.The CALL OUT signal is also emitted when HDD FULL in the <INITIAL SET UP> menu is set to “STOP”. In addition, while the CALL OUT sig- nal is not included in these settings, there is a setting for CALL OUT output when a problem occurs.

INFORMATION

For more on the relation between Warning Display and CALL OUT terminal, please refer to page 84. When the emission parameter in CALL OUT is set to “Fixed”, the warning display will appear unconditionally; when the parameter is set to “Selectable”, the unit can be made to emit a CALL OUT signal through additional settings. For example, when the BUZZER setting on the <REAR TERMINAL> menu is set to “WRNG”, the unit will sound a buzzer when the remaining amount on the hard disk has reached the figure specified on the <CALL OUT> menu.

Example: Setting CALL OUT of main HDD to “10%” (the default setting is “FULL”) and CALL OUT of archive me- dium to “20%” (the default is “NONE”).

1.Press the SET UP button to display the <MENU SETTING> menu.

2.Turn the JOG dial to move the cursor to REAR TERMINAL then turn the SHUTTLE ring to the right.

• The <REAR TERMINAL> menu will appear.

<REAR

TERMINAL>￿

REMAIN￿

@MODE

OUT

CAPACITY REMAIN HDD-10%

￿

CALL OUT

3.Turn the JOG dial until the cursor is next to “CALL OUT” and turn the SHUTTLE ring to the right to show the <CALL OUT> menu.

<CALL OUT>￿

@HDD(ID:0~3) FULL￿

ARCHIVE(ID:4) NONE

4.Confirm that the cursor is next to “HDD” and turn the SHUTTLE ring to the right to flash the sub-item.

<CALL OUT>￿

@HDD(ID:0~3) FULL￿

ARCHIVE(ID:4) NONE

5.Turn the JOG dial to flash “10%” and turn the SHUTTLE ring to the right to complete setting.

<CALL OUT>￿

@HDD(ID:0~3) 10%￿

ARCHIVE(ID:4) NONE

By turning the JOG dial, the item of CALL OUT shown on the screen switches as shown below:

FULL 2%4%6% 8% 10%

NONE50%40%30%20%15%

“NONE”: No signal is emitted from the CALL OUT terminal.