COMMUNICATION settings / Connecting to a personal computer

RS-232C settings

This connection can be used for remote control and re- cording supplementary information when the main unit is connected to a PC.

Transmission speed

Example: Transmission speed is set for 4800 bps.

1.Press the SET UP button to display the <MENU SETTING> menu.

2.Turn the JOG dial to move the cursor to C O M M U N I C A - TION SETTING then turn the SHUTTLE ring to the right.

The <COMMUNICATION SETTING> menu will appear.

<COMMUNICATION SETTING>￿ @RS-232C SETTING￿

TCP/IP SETTING

3.Check that the cursor is next to RS-232C SETTING and turn the SHUTTLE ring to the right.

The <RS-232C SETTING> menu will appear.

<RS-232C SETTING>￿

 

@TRANSMISSION RATE￿ 1200￿

DATA BIT LENGTH￿

8BIT￿

PARITY BIT￿

NONE￿

STOP BIT LENGTH￿

1BIT￿

DELIMITER

CR

4.Check that the cursor is next to TRANSMISSION RATE and turn the SHUTTLE ring to the right to flash the sub-item.

<RS-232C SETTING>￿

 

@TRANSMISSION RATE￿ 1200￿

DATA BIT LENGTH￿

8BIT￿

PARITY BIT￿

NONE￿

STOP BIT LENGTH￿

1BIT￿

DELIMITER

CR

<TCP/IP SETTING>￿

￿

￿

￿

￿

@SELF IP ADDRESS￿ 000.000.000.000￿

SUBNET MASK￿ 000.000.000.000￿

<MAC ADDRESS>￿

￿08-00-70-2E-3F-FF

4.Check that the cursor is next to SELF IP ADDRESS and turn the SHUTTLE ring to the right to flash the sub-item .

<TCP/IP SETTING>￿

￿

￿

￿

￿

@SELF IP ADDRESS￿ 000.000.000.000￿

SUBNET MASK￿ 000.000.000.000￿

<MAC ADDRESS>￿

￿08-00-70-2E-3F-FF

5.Turn the JOG dial to input the SELF IP ADDRESS and turn the SHUTTLE ring to the right to finish setting.

<TCP/IP SETTING>￿

￿

￿

￿

￿

@SELF IP ADDRESS￿ 192.168.001.100￿

SUBNET MASK￿ 255.255.255.000￿

<MAC ADDRESS>￿

￿08-00-70-2E-3F-FF

6.Press the SET UP button or turn the SHUTTLE ring to the left.

The <TCP/IP SETTING> menu will disappear.

ENGLISH

5.Turn the JOG dial to select “4800” and turn the SHUTTLE ring to the right to finish setting.

<RS-232C SETTING>￿

 

@TRANSMISSION RATE￿ 4800￿

DATA BIT LENGTH￿

8BIT￿

PARITY BIT￿

NONE￿

STOP BIT LENGTH￿

1BIT￿

DELIMITER

CR

6.Press the SET UP button.

The <RS-232C SETTING> menu will disappear.

TCP / IP settings

The IP address, subnet mask setting, and MAC address used to specify the connected recorder can be referred to here (refer to page 8).

Press the COMMUNICATION button on the unit’s front face to activate the TCP/IP communication

function.

1.Press the SET UP button to display the <MENU SETTING> menu.

2.Turn the JOG dial to move the cursor to C O M M U N I C A - TION SETTING then turn the SHUTTLE ring to the right.

The <COMMUNICATION SETTING> menu will appear.

<COMMUNICATION SETTING>￿ @RS-232C SETTING￿

TCP/IP SETTING

3.Turn the JOG dial to move the cursor to TCP / IP SETTING then turn the SHUTTLE ring to the right.

The <TCP / IP SETTING> menu will appear.

Connecting with a personal computer

This connection can be used for remote control and re- cording supplementary information when the main unit is connected to a PC.

Please use RS-232C Straight cable (9pin) to con- nect a modem with this unit. The setting of CTS

should be set to “HIGH” or “ON”. Please refer to the instruction manual of a modem for details about con- nection.

Connection via modem

Personal Comput

phone line

Modem Modem

RS-232C straight cable (9 pin)

Direct connection

Personal Computer

RS-232C crossover cable

Please use RS-232C crossover cable (9pin) to connect a modem with a personal computer. RS -

232C Crossover cable differs depending on the per- sonal computer.

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••