Using the Timer (continued) / Alarm Recording
4.Turn the JOG dial until “ON” flashes and turn the SHUTTLE ring to the right.
• The |
| |
|
| |
| ON | |
| @REC MODE (A) | |
| REC MODE (B) | OFF |
| REC MODE (C) | OFF |
| REC MODE (POWER) | OFF |
|
|
|
5.Turn the SHUTTLE ring to the left or press the SET UP button.
■Alarm Recording
When an alarm sensor connected to the ALARM IN termi- nal is triggered or the MOTION DETECTION function de- tect the motion, the unit will switch to the interval setting established for Alarm Recording.
When running in Alarm Recording mode, the unit will continue to record for the entire Alarm Record-
ing duration even if the
♦Alarm Recording operation
When the ALARM IN terminal is triggered or the MOTION DETECTION function detect the motion during normal op- eration, the unit will respond as shown in the illustration below.
Example: The unit is programmed for 2.5F recording inter- vals, and Alarm Recording is set at intervals of 6.25F and for a duration of 2 minutes.
ALARM SET IN or detect the motion
and turn the SHUTTLE ring to retrieve the entry. (Refer to page 58 for details on “Alarm List Search”.)
In addition, when the MOTION DETECTION set- ting on the <INITIAL SET UP> menu is set to “ON”,
please note that “MAN” cannot be selected for the Alarm Recording time.
1)Alarm Recording
2)As an index signal is also automatically stored at the beginning of Alarm Recording, the Alarm Recording start- time can also be retrieved using INDEX SEARCH. (Refer to page 57 for details on “Index Search”.)
♦Alarm Recording indicators
1)If the DISPLAY MODE is set for values other than 5 or 6, an Alarm Recordings count will automatically appear on- screen while the unit is running in Alarm Recording mode. (Refer to page 25 for details on DISPLAY MODE.)
2)The Alarm Recording indicator will flash on and off dur- ing Alarm Recording, and will stay on at the completion of Alarm Recording.
If the Alarm recording was made even once, the ALARM REC indicator would stay illuminating.
3)The Alarm Recording counter has a maximum of 9999. When this figure is exceeded, the count will return to 0001.
ENGLISH
recording at 2.5F | recording at 6.25F | recording at 2.5F |
|
|
|
normal recording | alarm recording | normal recording |
2minutes
♦Setting Alarm Recording
For details of the setting please refer to page 35.
♦Operations during Alarm Recording
1)An index signal will automatically be stored in memory when Alarm Recording begins.
Alarm recording number
00:00:00 25F | 50% C01 |
♦Operation after Alarm Recording
1)At the end of Alarm Recording, the unit will return to the same recording intervals which were in effect before the activation of Alarm Recording.
♦Indexing Alarm Recording time
When the RECORD ALARM on the
♦Alarm recording cameras
Please refer to “Camera Alarm Rec setting” on page 37 for details.
2)If the unit receives a new alarm signal or detect the motion while running in Alarm Recording mode, the unit will complete the Alarm Recording session initiated by the new signal.
3)If the unit receives an alarm signal while settings are being made on the
♦Alarm Recording time indicators
When Alarm Recording is started, the unit will store the date and time it receives the alarm signal. To access this data, press the SEARCH button to
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | Operations |
53