Using the Timer (continued)
Symptom 1)
The TIMER REC indicator is flashing. The buzzer sounds if the BUZZER setting is set to WRNG.
Reason for Error
1)The present time or the Timer is not set.
2)The timer program has been made on <TIMER PRO- GRAM> page, but the correct SELECTED PATTERN is not selected on the <TIMER PROGRAM> menu.
3)Menu setting is not yet completed.
Countermeasure
1)Set the correct present time (page 11).
2)Select the correct SELECTED PATTERN (page 50).
3)Complete the menu setting.
Symptom 2)
The Timer recording would not start even when the time is ready for timer recording.
Reason for Error
1)HDD FULL setting on the <INITIAL SET UP> menu is set to “STOP” or “ALARM•PROT”.
Countermeasure
1)Set the HDD FULL to other settings except “STOP” or “ALARM•PROT” (pages 30,54).
Symptom 3)
The Timer backup would not start even when the time is ready for timer backup.
Reason for Error
1) The medium of the peripheral device.
Countermeasure
1)Insert the new medium and press the WARNING RE- SET button to erase warning on screen. Press the TIMER REC button to release the timer, then press the TIMER REC button again.
♦Overlapping Timer settings
When Timer settings overlap, the unit will give priority to the
Example #1
•Program #1 is set for 14:00 to 17:00 with a recording interval of 2.5F.
•Program #2 is set for 15:00 to 16:00 with recording inter- val of 5F.
Under this condition, the unit will give priority to Program #2 for the duration of the overlapping period, from 15:00 to 16:00. The unit will operate as shown in the chart below.
Example 1)
14:00 | 15:00 | 16:00 | 17:00 | ||||
In Program #1, recording is set for every |
|
|
|
|
|
|
|
2.5F, from 14:00 to 17:00. |
|
|
| 2.5F |
|
| |
|
|
|
|
|
|
|
|
In Program #2, recording is set for |
|
|
|
|
|
|
|
|
|
| 5F |
|
|
| |
every 5F, from 15:00 to 16:00. |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
In this situation, the unit gives priority to the
14:00 | 15:00 | 16:00 | 17:00 | |||||
|
|
|
|
|
|
|
|
|
Actual recording will occur as follows. |
|
|
|
|
|
|
|
|
| 2.5F |
| 5F |
| 2.5F |
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Setting for the prioritized Program #2.
Example #2
•Program #1 is set for 14:00 to 17:00 with a recording interval of 2.5F.
•Program #2 is set for 15:00 to 16:00 with the SKIP setting.
Again, the unit will give priority to Program #2 for the duration of the overlapping period. As shown in the illustration below, the unit will activate the Skip setting from 15:00 to 16:00.
Example 2)
14:00 | 15:00 | 16:00 | 17:00 | ||||
In Program #1, recording is set for |
|
|
|
|
|
|
|
every 2.5F, from 14:00 to 17:00. |
|
|
| 2.5F |
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
In Program #2, the SKIP setting is |
|
|
|
|
|
|
|
|
|
| SKIP |
|
|
| |
entered for 15:00 to 16:00. |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
In this situation, the unit gives priority to the
14:00 | 15:00 | 16:00 | 17:00 | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| NO |
|
|
| |
Actual recording |
| 2.5F |
|
| 2.5F |
| ||
| RECORDING! |
|
| |||||
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Setting for the prioritized Program #2.
If TIMER REC is used while the unit is operating under the PRE
images using the conditions established in the PRE
♦M-DET APPLICATION setting
When a timer reservation is made while the motion detec- tion function is effective, the operation of the motion detec- tion function during execution of timer reservation can be set individually by camera operation and energization state.
When “POWER” has been selected as the op- eration setting in the <TIMER PROGRAM> menu,
the effectiveness of the execution of the motion de- tection function during the specified time in power ON state is set.
Example: Set “ON” as the
1.Press the SET UP button to display the <MENU SETTING> menu.
2.Move the cursor ( ) to TIMER PROGRAM then turn the SHUTTLE ring to the right.
•The <TIMER PROGRAM> menu will appear.
<TIMER PROGRAM> | P1 | |
@SELECTED | PATTERN | |
DEFINE P1 |
| |
DEFINE P2 |
| |
DEFINE P3 |
| |
|
| |
OFF | ||
REC MODE | (A) | |
REC MODE | (B) | OFF |
REC MODE | (C) | OFF |
REC MODE | (POWER) | OFF |
3.Turn the JOG dial to move the cursor to
•The
| |
OFF | |
@REC MODE (A) | |
REC MODE (B) | OFF |
REC MODE (C) | OFF |
REC MODE (POWER) | OFF |
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | •••••••••••• | • |
52