I/O terminals

GND terminals

The ground terminals for Input/Output terminals.

CLOCK ADJ terminal

Input terminal to set the present time. Time display is adjusted to the nearest hour (00 minutes 00 seconds) when this terminal receives the CLOCK ADJ signal.

REC terminal

Input terminal to start recording.

POWER ON terminal

Input terminal to turn on this unit through a peripheral device.

POWER OFF terminal

Input terminal to turn off this unit through a peripheral device.

ALARM OUT terminal

Output terminal to indicate that the alarm recording is in process.

MODE OUT terminal

Output terminal to indicate the unit’s current mode. Se- lect the unit’s condition by MODE OUT setting in the <REAR TERMINAL> menu.

CALL OUT terminal / CALL OUT GND terminal

This is the ISOLATION output terminal. (Refer to page 85.) Output terminal and its GND terminal to indicate in- formation such as “HDD FULL”. Information that can be transmitted externally consists of CALL OUT settings made on the I/O terminal settings menu screen as well as fixed output settings.

DC 5V OUT terminal

This terminal is for direct current voltage output. The maximum electric current is 30mA.

ENGLISH

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Beginning

9

Page 9
Image 9
Mitsubishi Electronics DX-TL1600EM operation manual Terminals