Operation examples

Operation example 1: Simultaneous Backup using the Timer

The Timer can be used for making weekly data backups when the unit is running in continuous recording mode.The unit will automatically eject the storage medium upon com- pletion of the backup, and a new one may then be inserted into the machine.

System configuration

Example of a system using the following peripherals:

16 video cameras

Archive device connected to ID4

Monitor

(Up to 16 cameras)

Monitor

ID4: archive device

Images provided by each of the connected cameras are recorded 24 hours a day, and the unit will make a backup of one week’s volume of image data while it continues to record current images. The unit records one field per second and IMAGE QUALITY is set to “BASIC”, a recording rate of one field per 16 seconds for each camera.

00 : 00

24 : 00

From Monday

 

 

 

 

 

 

24-hours recording

 

to Sunday

 

 

 

 

 

 

 

00 : 00

05 : 00

 

Sunday

 

 

 

 

Archive

 

 

 

 

 

Archive media auto eject

Settings

1) Record settings are made as follows.

• Set IMAGE QUALITY to “BASIC”.

<NORMAL REC SETTING>￿

@IMAGE QUALITY

BASIC￿

MAX REC FIELDS

1F￿

SELECT REC MODE

(A)￿

DEFINE GROUP SETTING￿

￿

 

￿

 

￿

 

￿

 

￿

 

<ESTD TIME>

48D21H31M

The capability to record continuously over a one- week period is dependent on the settings for IM-

AGE QUALITY and MAX REC FIELDS. For details on the relationship between intervals and image quality, refer to “Recording time table” on page 81.

• Set MAX REC FIELDS to “1F”.

• Set HDD FULL to “REPEAT”.

<INITIAL SET UP>￿

 

TIME DATE ADJUST￿

REPEAT￿

@HDD

FULL￿

HDD

PB REPEAT￿

STOP￿

ARCHIVE OVERWRITE

OFF

2)Camera settings and camera title settings are made as follows.

Make the settings for the 16 cameras listed under (A) on the <DEFINE GROUP SETTING> menu.

<DEFINE GROUP>

 

 

(A)￿

CH PRI FILD CH PRI FILD￿

@Q

1

0.09

O

1

0.09￿

W

1

0.09

P

1

0.09

E

1

0.09

{

1

0.09

R

1

0.09

}

1

0.09

T

1

0.09

q

1

0.09

Y

1

0.09

w

1

0.09

U

1

0.09

e

1

0.09

I

1

0.09

r

1

0.09

￿

 

 

 

 

 

The number of cameras used in each of the opera- tional modes A, B, C can be adjusted. Refer to page 13 for details.

<CAMERA TITLE>￿

CH TITLE￿

@1 ENTRANCE........￿

2ATM1............￿

3 ATM2............￿

4 COUNTER1........￿

5 COUNTER2........￿

6 COUNTER3........￿

7 VAULT...........￿

8 EXIT............￿

3)Enter the following settings under P1 on the <TIMER PROGRAM> menu:

• In Timer programming number 1, set the action to “A– 1” for the daily start time of 00:00 to the next day’s end time of 00:00. (This setting activates, for all of the cameras in operational mode A, a recording rate of one frame per second.)

In Timer programming number 2, set the action to “EJECT” for Sunday’s start time of 00:00 to end time of 05:00.

<TIMER PROGRAM>

P1￿

 

DW

START END MODE￿

@ DAY

00:00¥00:00 AÐ

1￿

2

SUN

00:00 05:00 EJECT￿

3

ÐÐÐ

ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐ￿

4

ÐÐÐ

ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐ￿

The symbol “” will appear between the start- time and end-time columns. This symbol indicates

that recording will continue until the following day.

INFORMATION

“SKIP”: This is set when timer recording is to be paused temporarily. Then the power will be switched off and the specified time period for that program number will not be recorded.

“POWER”: During the specified time, the power sup- ply is stopped in “ON” condition. This is used for execution of alarm recording during timer reserva- tion.

“ARC”(ARCHIVE): The recording contents of the HDD are backed up to the backup device.

“EJECT”: After backup of the recording contents of the HDD to the backup device, the medium is ejected automatically.

ENGLISH

••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

Operations

47

Page 47
Image 47
Mitsubishi Electronics DX-TL1600EM Operation examples, Operation example 1 Simultaneous Backup using the Timer