Operation examples
■Operation example 1: Simultaneous Backup using the Timer
The Timer can be used for making weekly data backups when the unit is running in continuous recording mode.The unit will automatically eject the storage medium upon com- pletion of the backup, and a new one may then be inserted into the machine.
System configuration
Example of a system using the following peripherals:
•16 video cameras
•Archive device connected to ID4
•Monitor
(Up to 16 cameras)
Monitor
ID4: archive device
Images provided by each of the connected cameras are recorded 24 hours a day, and the unit will make a backup of one week’s volume of image data while it continues to record current images. The unit records one field per second and IMAGE QUALITY is set to “BASIC”, a recording rate of one field per 16 seconds for each camera.
00 : 00 | 24 : 00 | |||
From Monday |
|
|
|
|
|
|
| ||
to Sunday |
|
|
| |
|
|
|
| |
00 : 00 | 05 : 00 |
| ||
Sunday |
|
|
|
|
Archive |
|
| ||
|
|
| ||
Archive media auto eject |
Settings
1) Record settings are made as follows.
• Set IMAGE QUALITY to “BASIC”.
<NORMAL REC SETTING>
@IMAGE QUALITY | BASIC |
MAX REC FIELDS | 1F |
SELECT REC MODE | (A) |
DEFINE GROUP SETTING | |
| |
| |
| |
| |
|
<ESTD TIME> | 48D21H31M |
The capability to record continuously over a one- week period is dependent on the settings for IM-
AGE QUALITY and MAX REC FIELDS. For details on the relationship between intervals and image quality, refer to “Recording time table” on page 81.
• Set MAX REC FIELDS to “1F”.
• Set HDD FULL to “REPEAT”.
<INITIAL SET UP> |
| |
TIME DATE ADJUST | REPEAT | |
@HDD | FULL | |
HDD | PB REPEAT | STOP |
ARCHIVE OVERWRITE | OFF |
2)Camera settings and camera title settings are made as follows.
•Make the settings for the 16 cameras listed under (A) on the <DEFINE GROUP SETTING> menu.
<DEFINE GROUP> |
|
| (A) | ||
CH PRI FILD CH PRI FILD | |||||
@Q | 1 | 0.09 | O | 1 | 0.09 |
W | 1 | 0.09 | P | 1 | 0.09 |
E | 1 | 0.09 | { | 1 | 0.09 |
R | 1 | 0.09 | } | 1 | 0.09 |
T | 1 | 0.09 | q | 1 | 0.09 |
Y | 1 | 0.09 | w | 1 | 0.09 |
U | 1 | 0.09 | e | 1 | 0.09 |
I | 1 | 0.09 | r | 1 | 0.09 |
|
|
|
|
|
The number of cameras used in each of the opera- tional modes A, B, C can be adjusted. Refer to page 13 for details.
<CAMERA TITLE>
CH TITLE
@1 ENTRANCE........
2ATM1............
3 ATM2............
4 COUNTER1........
5 COUNTER2........
6 COUNTER3........
7 VAULT...........
8 EXIT............
3)Enter the following settings under P1 on the <TIMER PROGRAM> menu:
• In Timer programming number 1, set the action to “A– 1” for the daily start time of 00:00 to the next day’s end time of 00:00. (This setting activates, for all of the cameras in operational mode A, a recording rate of one frame per second.)
•In Timer programming number 2, set the action to “EJECT” for Sunday’s start time of 00:00 to end time of 05:00.
<TIMER PROGRAM> | P1 | ||
| DW | START END MODE | |
@ DAY | 00:00¥00:00 AÐ | 1 | |
2 | SUN | 00:00 05:00 EJECT | |
3 | ÐÐÐ | ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐ | |
4 | ÐÐÐ | ÐÐ:ÐÐ ÐÐ:ÐÐ ÐÐÐÐÐÐ |
The symbol “” will appear between the start- time and
that recording will continue until the following day.
INFORMATION
“SKIP”: This is set when timer recording is to be paused temporarily. Then the power will be switched off and the specified time period for that program number will not be recorded.
“POWER”: During the specified time, the power sup- ply is stopped in “ON” condition. This is used for execution of alarm recording during timer reserva- tion.
“ARC”(ARCHIVE): The recording contents of the HDD are backed up to the backup device.
“EJECT”: After backup of the recording contents of the HDD to the backup device, the medium is ejected automatically.
ENGLISH
•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••• | Operations |
47