Major operations and their functions (continued)

Rear View

1

2

3

4

 

 

 

 

 

 

 

CAMERA IN

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

11

12

13

14

15

16

 

 

 

 

 

 

 

CAMERA OUT

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

 

10

11

12

13

14

15

16

 

 

 

1 2 3 4 5 6 7 8 9

10 11 12 13 14 15 16

GND CLOCKADJ

REC POWERON

POWEROFF ALARMOUT MODEOUT

OUTCALL OUTCALLGND GND GND 5VDCOUT

30mAMAX

 

 

 

 

 

 

 

 

 

 

GND

GND

 

 

 

 

 

ON

OFF

 

 

 

 

 

ETHERNET

 

 

ALARM IN

 

 

 

 

 

 

SCSI

 

 

 

 

 

RS-232C

 

 

 

 

 

 

 

 

RESET TERMINATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCSI

 

 

 

 

 

VIDEO OUT

Y/C

5

6

7

8

9

10

1. CAMERA IN connectors

6. RS-232C socket

Input connector for signal of camera (BNC connec- tor).

2. CAMERA OUT connectors

Output connector for signal of camera which is pro- vided via CAMERA IN (BNC connector).

3. VIDEO OUT connectors

Output connector for video signal to monitor(BNC connector).

S(Y/C) OUT connector

Output connector for separate Luminance and Chrominance signal. Output signal with VIDEO OUT connector at the same time.

4. AC power socket

This socket connects to the power cord. Earth ter- minal is for safety. Use the 100 - 240V plug with earth for the power of this unit.

Do not connect the earth terminal of a plug to gas pipe, water pipe, lightning rod and so on.

5. ETHERNET socket

Use in combination with the PC software DX-PC3. For further information, please refer to the DX-PC3 user’s manual. Use a 10BaseT cable to connect to the Ethernet terminal. Please note, however, that only category 3 and category 5 10BaseT cables can be used. Please do not connect the unit to a com- mon network.

This terminal is used to connect to host device with RS-232C terminal. This unit can be control- led by the other device through this terminal.

7. ALARM IN terminals

Input terminal for alarm signal.

GND terminals

Input ground terminal for ALARM IN terminal. Use only the terminal for this unit. It may cause dam- age or poor connection.

8. I/O terminals

Refer to notes on page 9.

9. SCSI terminal

This terminal is for connecting this unit to other optional peripheral recording devices.

10. RESET button

When pressed, the present time is erased and ini- tialized, then the power is turned off.

SCSI TERMINATION switch

When set to “ON”, the internal terminator function is active, and when set to “OFF”, the function is provided by the peripheral device. Set it to “ON” when not connecting to a peripheral SCSI device.

•••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••

•••••••••••••