Mitsubishi Electronics PUY-A18NHA2-BS, PUZ-A42NHA2-BS 102, Fan control state Request code

Models: PUZ-A36NHA2-BS PUY-A12NHA2 PUY-A42NHA2-BS PUY-A30NHA2 PUZ-A36NHA2 PUY-A36NHA2-BS PUZ-A18NHA2 PUZ-A18NHA2-BS PUY-A30NHA2-BS PUZ-A30NHA2-BS PUY-A18NHA2 PUY-A36NHA2 PUZ-A30NHA2 PUY-A12NHA2-BS PUZ-A24NHA2-BS PUZ-A42NHA2 PUY-A18NHA2-BS PUY-A42NHA2 PUZ-A42NHA2-BS PUY-A24NHA2-BS PUZ-A24NHA2 PUY-A24NHA2

1 120
Download 120 pages 22.49 Kb
Page 102
Image 102

[Fan control state] (Request code :" 53 ")

Data display

0 0

Fan step correction value by heatsink temperature overheat prevention control

Fan step correction value by cool condensation temperature overheat prevention control

Display

Correction value

- (minus)

– 1

0

0

1

+1

2

+2

[Actuator output state] (Request code :"54")

Data display

0

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Actuator output state 1

 

 

 

 

 

 

 

 

 

Actuator output state 2

 

Actuator output state 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display

 

SV1

 

 

Four-way valve

Compressor

 

Compressor is

 

 

 

 

warming up

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

1

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

ON

 

 

 

3

 

ON

 

 

 

 

ON

 

 

 

4

 

 

 

 

 

 

 

 

ON

 

 

5

 

ON

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

ON

ON

 

 

7

 

ON

 

 

 

 

ON

ON

 

 

8

 

 

 

 

 

 

 

 

 

 

ON

9

 

ON

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

ON

 

 

ON

b

 

ON

 

 

 

 

ON

 

 

ON

C

 

 

 

 

 

 

 

 

ON

 

ON

d

 

ON

 

 

 

 

 

ON

 

ON

E

 

 

 

 

 

 

 

ON

ON

 

ON

F

 

ON

 

 

 

 

ON

ON

 

ON

Actuator output state 2

Display

52C

SV2

SS

 

 

 

 

0

 

 

 

1

ON

 

 

 

 

 

 

2

 

ON

 

3

ON

ON

 

4

 

 

ON

5

ON

 

ON

6

 

ON

ON

7

ON

ON

ON

[Error content (U9)] (Request code :"55 ")

Data display

 

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error content 1

 

 

 

 

 

 

 

Error content 2

 

Error content 1

 

 

 

 

 

: Detected

 

 

 

 

 

Display

Overvoltage

Undervoltage

L1-phase

Power synchronizing

 

error

 

error

open error

signal error

 

 

 

0

1

2

3

4

5

6

7

8

9

A

b

C

d

E

F

Error content 2

: Detected

Display Converter Fo

PAM error

error

 

0

 

1

 

2

 

3

 

102

Page 102
Image 102
Mitsubishi Electronics PUY-A18NHA2-BS, PUZ-A30NHA2 102, Fan control state Request code, Actuator output state Request code