Mitsubishi Electronics PUZ-A24NHA2, PUZ-A42NHA2-BS, PUZ-A30NHA2, PUY-A36NHA2 HOW to Check the Parts

Models: PUZ-A36NHA2-BS PUY-A12NHA2 PUY-A42NHA2-BS PUY-A30NHA2 PUZ-A36NHA2 PUY-A36NHA2-BS PUZ-A18NHA2 PUZ-A18NHA2-BS PUY-A30NHA2-BS PUZ-A30NHA2-BS PUY-A18NHA2 PUY-A36NHA2 PUZ-A30NHA2 PUY-A12NHA2-BS PUZ-A24NHA2-BS PUZ-A42NHA2 PUY-A18NHA2-BS PUY-A42NHA2 PUZ-A42NHA2-BS PUY-A24NHA2-BS PUZ-A24NHA2 PUY-A24NHA2

1 120
Download 120 pages 22.49 Kb
Page 55
Image 55

10-6. HOW TO CHECK THE PARTS

PUZ-A18/24/30/36/42NHA2 PUZ-A18/24/30/36/42NHA2-BS PUY-A12/18/24/30/36/42NHA2 PUY-A12/18/24/30/36/42NHA2-BS

Parts name

 

 

 

 

 

 

 

 

 

 

Check points

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor (TH3)

Disconnect the connector then measure the resistance with a tester.

<Outdoor pipe>

 

(At the ambient temperature 10:~30:, 50˚F~86˚F)

 

 

 

 

 

 

 

Thermistor (TH4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

Abnormal

 

 

 

 

 

 

 

<Discharge>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH4

 

 

160k"~410k"

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor (TH6)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

<Outdoor 2-phase pipe>

 

TH3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor (TH7)

 

TH6

 

 

4.3k"~9.6k"

 

 

Open or short

 

 

 

 

 

<Outdoor>

 

 

 

TH7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thermistor (TH8)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TH8

 

 

39k"~105k"

 

 

 

 

 

 

 

 

 

 

 

 

<Heatsink>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan motor(MF1,MF2)

Refer to next page.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid valve coil

Measure the resistance between the terminals with a tester.

<Four-way valve>

(At the ambient temperature 20:, 68˚F)

 

 

 

 

 

 

 

 

 

 

 

 

(21S4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

Abnormal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A18-36

 

 

 

A42

 

 

 

 

Open or short

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1500±150"

 

 

 

 

2350±170"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor for compressor

Measure the resistance between the terminals with a tester.

 

 

 

 

 

 

 

(MC)

 

U

(Winding temperature 20:, 68˚F)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

 

 

 

 

 

Abnormal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V

 

A12, 18

 

A24, 30, 36

 

 

 

A42

 

 

Open or short

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

W

 

0.320"

 

 

0.880"

 

 

 

 

0.266"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Linear expansion valve

Disconnect the connector then measure the resistance with a tester.

(LEV-A)

 

 

(Winding temperature 20:, 68˚F)

 

 

 

 

 

 

 

 

 

 

 

 

For A12, 18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

Abnormal

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Brown

2

 

Red - White

 

Red - Orange

 

Brown - Yellow

 

Brown - Blue

 

 

 

Blue

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open or short

 

 

 

 

 

 

46±4"

 

 

 

 

 

 

 

 

 

 

Orange

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

White

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Linear expansion valve

Disconnect the connector then measure the resistance with a tester.

(LEV-A)

 

 

(Winding temperature 20:, 68˚F)

 

 

 

 

 

 

 

 

 

 

 

 

For A24-42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gray

 

 

 

 

 

 

Normal

 

 

 

 

 

 

 

 

Abnormal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gray - Black

 

Gray - Red

 

Gray - Yellow

 

 

Gray - Orange

 

 

 

 

 

 

2

 

 

 

 

 

 

 

Orange

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Open or short

 

 

 

 

 

 

46±3"

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Yellow

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Solenoid valve coil

Measure the resistance between the terminals with a tester.

 

 

 

 

 

 

 

(At the ambient temperature 20:, 68˚F)

 

 

 

 

 

 

 

 

 

 

 

 

<Bypass valve>

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(SV)

 

 

 

Normal

 

 

 

 

 

Abnormal

 

 

 

 

 

 

 

For A24-36 only

 

 

1450±150"

 

 

 

Open or short

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

55

Page 55
Image 55
Mitsubishi Electronics PUZ-A24NHA2, PUZ-A42NHA2-BS, PUZ-A30NHA2, PUY-A36NHA2, PUZ-A18NHA2-BS HOW to Check the Parts