Mitsubishi Electronics PUZ-A24NHA2, PUZ-A42NHA2-BS, PUZ-A30NHA2, PUY-A36NHA2 Code Description

Models: PUZ-A36NHA2-BS PUY-A12NHA2 PUY-A42NHA2-BS PUY-A30NHA2 PUZ-A36NHA2 PUY-A36NHA2-BS PUZ-A18NHA2 PUZ-A18NHA2-BS PUY-A30NHA2-BS PUZ-A30NHA2-BS PUY-A18NHA2 PUY-A36NHA2 PUZ-A30NHA2 PUY-A12NHA2-BS PUZ-A24NHA2-BS PUZ-A42NHA2 PUY-A18NHA2-BS PUY-A42NHA2 PUZ-A42NHA2-BS PUY-A24NHA2-BS PUZ-A24NHA2 PUY-A24NHA2

1 120
Download 120 pages 22.49 Kb
Page 99
Image 99

code

 

Description

Request

Request content

(Display range)

 

 

 

103

Error history 1 (latest)

Displayserrorhistory.("--" isdisplayedifnohistoryispresent.)

104

Error history 2 (second to last)

Displayserrorhistory.("--" isdisplayedifnohistoryispresent.)

105

Error history 3 (third to last)

Displayserrorhistory.("--" isdisplayedifnohistoryispresent.)

 

 

3 : F TH3

 

Abnormal thermistor display

6 : F TH6

106

7 : F TH7

(TH3/TH6/TH7/TH8)

 

 

8 : F TH8

 

 

0 : F No thermistor error

107

Operation mode at time of error

Displayed in the same way as request code "0".

108

Compressor-Operating current at time of error

0 – 50

109

Compressor-Accumulated operating time at time of error

0 – 9999

110

Compressor-Number of operation times at time of error

0 – 9999

111

Discharge temperature at time of error

37 ~ 327

112

Outdoor unit - Liquid pipe 1 temperature (TH3) at time of error

-40 ~ 194

113

Outdoor unit - Liquid pipe 2 temperature at time of error

-40 ~ 194

114

Outdoor unit-2-phase pipe temperature (TH6) at time of error

-38 ~ 190

115

 

 

116

Outdoor unit-Outside air temperature (TH7) at time of error

-38 ~ 190

117

Outdoor unit-Heat sink temperature (TH8) at time of error

-40 ~ 327

118

Discharge super heat (SHd) at time of error

0 – 327

119

Sub-cool (SC) at time of error

0 – 234

120

Compressor-Operating frequency at time of error

0 – 255

121

Outdoor unit at time of error

0 – 10

• Fan output step

 

 

122

Outdoor unit at time of error

0 – 9999

• Fan 1 speed (Only for air conditioners with DC fan)

 

 

123

Outdoor unit at time of error

0 – 9999

• Fan 2 speed (Only for air conditioners with DC fan)

 

 

124

 

 

125

LEV (A) opening at time of error

0 – 500

126

LEV (B) opening at time of error

0 – 500

127

 

 

128

 

 

129

 

 

130

Thermostat ON time until operation stops due to error

0 – 999

131

 

 

132

Indoor - Liquid pipe temperature at time of error

-38 ~ 190

 

133

Indoor-2-phase pipe temperature at time of error

-38 ~ 190

 

134

Indoor at time of error

-38 ~ 190

• Intake air temperature <Thermostat judge temperature>

 

 

135

 

 

136

 

 

137

 

 

138

 

 

139

 

 

140

 

 

~

 

 

146

 

 

147

 

 

148

 

 

149

 

 

150

Indoor-Actual intake air temperature

-38 ~ 190

151

Indoor - Liquid pipe temperature

-38 ~ 190

152

Indoor-2-phase pipe temperature

-38 ~ 190

 

 

 

Unit

Remarks

Code

Code

Code

Sensor number

A

10hours 100 times

˚F

˚F

˚F

˚F

˚F

˚F

˚F

˚F

Hz

Step

rpm

"0" is displayed if the air conditioner is a single-

rpm

fan type.

Pulses

Pulses

Minutes

Average value of all indoor units is displayed if the air condi-

˚F

tioner consists of two or more indoor units (twin, triple, quad).

Average value of all indoor units is displayed if the air condi-

˚F

tioner consists of two or more indoor units (twin, triple, quad).

˚F

˚F

˚F

˚F

99