Carrier Modulator Transmitter (CMT)
MCGEN — Modulator and Carrier Generator Enable
Setting MCGEN will initialize the carrier generator and modulator and will enable all clocks. Once enabled, the carrier generator and modulator will function continuously. When MCGEN is cleared, the current modulator cycle will be allowed to expire before all carrier and modulator clocks are disabled (to save power) and the modulator output is forced low. The user should initialize all data and control registers before enabling the system to prevent spurious operation. This bit is cleared by reset.
1 = Modulator and carrier generator enabled
0 = Modulator and carrier generator disabled
General Release Specification |
| MC68HC05RC16 — Rev. 3.0 |
|
|
|
82 | Carrier Modulator Transmitter (CMT) | MOTOROLA |