15-4 MC68VZ328 User’s Manual
Programming Model
15.4 Programming Model
This section contains programming information about both PWM 1 and PWM 2.

15.4.1 PWM 1 Control Register

This register controls the operation of the pulse-width modulator, and it also contains the status of the
PWM 1 FIFO. The register bit assignments are shown in the following register display. The register
settings are described in Table15-1.

PWMC1 PWM 1 Control Register 0x(FF)FFF500

BIT 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 BIT 0
CLKSRC PRESCALER IRQ IRQEN FIFOAV EN REPEAT CLKSEL
TYPE rw rw rw rw rw rw rw rw rw rw rw rw w w rw rw
RESET 0 00000000 0 1 00 00 0
0x0020
Table 15-1. PWM 1 Control Register Description
Name Description Setting
CLKSRC
Bit 15 Clock Source—This bit is used to select the
clock source to the pulse-width modulator. 0 = SYSCLK source is selected (default).
1 = CLK32 is selected.
Note: 32.768 kHz clock source is selected
when using a 32.768 kHz crystal. If a 38.4kHz
crystal is used, 38.4kHz is selected.
PRESCALER
Bits 14–8 Prescaler—This field is used to scale down
the incoming clock to divide by the
prescaler+ 1. The prescaler is normally used
to generate a low single-tone PWMO signal.
For voice modulation, these bits are set to 0
(divide by 1). The default value is 0.
Any value between 0 and 127.
IRQ
Bit 7 Interrupt Request—This bit indicates that the
FIFO has one or no bytes remaining, which
can be a signal of the need to fill the FIFO by
writing no more than two 16-bit words into the
PWMS register. This bit automatically clears
itself after this register is read, thus eliminating
an extra write cycle in the interrupt service rou -
tine. If the IRQEN bit is 0, this bit can be polled
to indicate the status of the period comparator.
This bit can be set to immediately post a PWM
interrupt for debugging purposes.
0 = The FIFO is not empty.
1 = The FIFO has one or no sample bytes
remaining.
IRQEN
Bit 6 Interrupt Request Enable—This bit controls
the pulse-width modulator interrupt. While this
bit is low, the interrupt is disabled.
0 = The PWM interrupt is disabled (default).