Motorola SG 2000 Level Control, Options and Accessories, Model Description Function, Adu

Models: SG 2000

1 105
Download 105 pages 11.1 Kb
Page 27
Image 27

2 - 1 4

O v e r v i e w

Level Control

The gain of hybrid IC amplifiers varies with temperature. In addition, changes in system channel loading and/or splices in the fiber link can change the level of the received signal.

The standard TCU board compensates for anticipated hybrid gain changes by sensing housing temperature and signaling needed changes to the RF attenuator.

The ADU board, an optional plug-in module, monitors the amplitude of a selected pilot frequency. The pilot frequency is an available analog television channel not scrambled by the sync suppression method. Any changes in amplitude are fed back to the RF attenuator that makes appropriate corrections.

The input to the ADU contains a JXP-* pad. The factory-installed value of this pad is 6 dB (JXP-6) for bridger level outputs and 0 dB (JXP-ZX) for trunk level outputs. Under normal conditions, it should not be changed.

Options and Accessories

Table 2-3 provides a list of options and accessories for the SG 2000:

Table 2-3

Options and accessories

Model

Description

Function

ADU-*

Automatic drive

This option automatically adjusts gain by monitoring changes

 

unit

in the level of the selected pilot carrier. Either an ADU or TCU

 

 

must be installed.

TCU

Thermal control

The TCU controls amplifier gain for changes in hybrid gain at

 

unit

the sensed temperature.

JXP-*A

Fixed

Attenuator pads are used to adjust amplifier levels and are

 

attenuator

available in 1 dB steps from 1 through 24 dB. The appropriate

 

 

value must be installed.

JXP-ZX

0 dB attenuator

This attenuator is used in place of JXP-*A pads when no

 

 

attenuation is needed.

FTEC

Crowbar

The FTEC is an electronic crowbar/surge protector that can be

 

overvoltage

used to replace the existing 230-volt gas discharge surge

 

protection

protector.

LL-SG2

LIFELINE

This module enables the system operator to monitor the SG2

 

module

from a remote location. See Section 5, “Operation” for

 

 

parameters monitored. Several frequencies are available. See

 

 

the product catalog for additional information.

GFAL

Test probe

This probe is used to evaluate node performance.

F/JXP

Injection probe

This probe is used to inject a signal for test purposes.

SG 2000 Installation and O peration Manual

Page 27
Image 27
Motorola SG 2000 Level Control, Options and Accessories, Model Description Function, Options and accessories, Adu