Ingress Control

The SG 2000 platform incorporates electronic ingress control switching enabling operators to choose one of three options for troubleshooting noise sources. A maximum of four switches, (one ingress switch per RF port) can populate the RF amplifier. Figure 3-2 illustrates their location on the RF chassis.

Ingress switches are controlled in one of two ways: (1) remotely — through the optional on-board LL-SG2 transponder in communication with the status monitoring system or; (2) locally — using the manual control board (MCB).

The three states of the switch and their functions include:

State

Description

Off

Effectively isolates the contaminated leg by adding a minimum of 40 dB attenuation.

–6 dB

Typically initiated at the headend, it provides –6 dB additional attenuation to the return

 

signal. This is useful in diagnosing noise presence without interfering with normal

 

service.

On

Completes the return path without alteration to the return signal.