O p e r a t i o n

5 - 2 1

Table 5-8 provides information on the user-related features of the DS-SG2-DRT/A transmitters:

Table 5-8

DS-SG2-DRT/A features

Feature

Test point A

Input A

Increment attenuator setting

Decrement attenuator setting

Change increment/ decrement direction

Restore factory default setting

Status

Alarms

No alarm

Over temperature (> + 85°C) Low + 24 Vdc (< + 18 Vdc) Low + 5 Vdc (< + 4.5 Vdc) Low + 2.5 Vdc (< + 2.2 Vdc)

Laser bias/optical power out of spec.

Description

This test point enables monitoring of the RF level at the input to the A/D. It measures 20 dB from the A/D input level.

The transmitter has a digitally controlled attenuator that adjusts for varying input levels. This push-button is an input level-control adjustment that provides + 2 to 13 dB of adjustment from an input level of 15 dBmV.

Short press (0.1 to 1.5 seconds). The status LED indication is green with a short OFF blink (0.25 sec.) when the button is released. A short red blink occurs if the increment attempts to go past the maximum.

Short press (0.1 to 1.5 seconds). The status LED indication is green with a short yellow blink (0.25 sec.) when the button is released. A short red blink occurs if the decrement attempts to go past the minimum.

Medium press (1.5 to 5.0 seconds). The status LED is OFF after

1.5seconds when in the increment direction, and yellow when in the decrement direction. The LED is restored to its green or alarm state when the button is released. No increment or decrement occurs.

Long press (5.0 seconds or longer). The status LED flashes green and yellow rapidly until the button is released. After five seconds of flashing, the factory defaults are restored.

This tri-color LED is green if all parameters are within specification. A series of red flashes indicate an alarm condition. The number of red flashes indicate the parameter that is outside the specification.

Status LED indication:

Steady green

Long red, one red flash (repeating) Long red, two red flashes (repeating) Long red, three red flashes (repeating) Long red, five red flashes (repeating) Long red, six red flashes (repeating)

It is recommended that you restore the factory default settings before you set up the node levels. This procedure places the transmitter input level 2 dB below maximum.

SG 2000 Installation and O peration Manual

Page 85
Image 85
Motorola SG 2000 operation manual Feature, DS-SG2-DRT/A features