O p e r a t i o n | 5 - 2 1 |
Table
Table
DS-SG2-DRT/A features
Feature
Test point A
Input A
Increment attenuator setting
Decrement attenuator setting
Change increment/ decrement direction
Restore factory default setting
Status
Alarms
No alarm
Over temperature (> + 85°C) Low + 24 Vdc (< + 18 Vdc) Low + 5 Vdc (< + 4.5 Vdc) Low + 2.5 Vdc (< + 2.2 Vdc)
Laser bias/optical power out of spec.
Description
This test point enables monitoring of the RF level at the input to the A/D. It measures − 20 dB from the A/D input level.
The transmitter has a digitally controlled attenuator that adjusts for varying input levels. This
Short press (0.1 to 1.5 seconds). The status LED indication is green with a short OFF blink (0.25 sec.) when the button is released. A short red blink occurs if the increment attempts to go past the maximum.
Short press (0.1 to 1.5 seconds). The status LED indication is green with a short yellow blink (0.25 sec.) when the button is released. A short red blink occurs if the decrement attempts to go past the minimum.
Medium press (1.5 to 5.0 seconds). The status LED is OFF after
1.5seconds when in the increment direction, and yellow when in the decrement direction. The LED is restored to its green or alarm state when the button is released. No increment or decrement occurs.
Long press (5.0 seconds or longer). The status LED flashes green and yellow rapidly until the button is released. After five seconds of flashing, the factory defaults are restored.
This
Status LED indication:
Steady green
Long red, one red flash (repeating) Long red, two red flashes (repeating) Long red, three red flashes (repeating) Long red, five red flashes (repeating) Long red, six red flashes (repeating)
It is recommended that you restore the factory default settings before you set up the node levels. This procedure places the transmitter input level 2 dB below maximum.