Auxiliary Relay Control

ISI5634PCI/4/8 User Guide

Command: &Jn

Auxiliary Relay Control

Values:

n = 0

Default:

0

Description: &J0

The auxiliary relay is never closed.

&J1

Not supported—responds ERROR.

Command: &Kn

Flow Control Selection

Values:

n = 0, 3, or 4

Defaults:

3

Description: &K0

Disable flow control.

&K3

Enable CTS/RTS hardware flow control.

&K4

Enable XON/XOFF software flow control.

Command: &Mn

CommunicationsMode

Values:

n = 0

Defaults:

0

Description: &M0

Asynchronous mode.

&M1

Not supported—responds ERROR.

Command: &Qn

AsynchronousCommunicationsMode

Values:

n = 0, 5, 6, 8, or 9

Default:

5

Description: &Q0

Asynchronous with data buffering. Same as \N0.

&Q5

Error control with data buffering. Same as \N3.

&Q6

Asynchronous with data buffering. Same as \N0.

&Q8

MNP error control mode. If MNP error control is not

 

established, the modem falls back according to the set-

 

ting in S36.

&Q9

V.42 or MNP error control mode. If neither error control

 

is established, the modem falls back according to the

 

setting in S36.

Command: &Sn

Data Set Ready (DSR) Control

Values:

n = 0 or 1

Default:

0

Description: &S0

Forces DSR always high (on).

&S1

Lets DSR go high only during a connection.

84