Chapter 4—AT Commands, S-Registers, Result Codes

Command: DS=y Dial Stored Telephone Number

Values:

n = 0–3

Default:

none

Description:

Dial a number previously stored in directory number y

 

by the &Zy=x command.

 

Example:ATDS=3

Command: En

EchoCommandModeCharacters

Values:

n = 0 or 1

Default:

1

Description: E0

Do not echo keyboard input to the terminal.

E1

Do echo keyboard input to the terminal.

Command: Fn

Echo Online Data Characters

Values:

n = 1

Default:

1

Description: F0

Enable online data character echo. (Not supported.)

F1

Disable online data character echo (included for back-

 

ward compatibility with some software).

Command: Hn

HookControl

Values:

n = 0 or 1

Default:

0

Description: H0 Go on-hook (hang up).

H1

Go off-hook (make the phone line busy).

Command: In

InformationRequest

Values:

n = 0–5, 9, 11

Default:

None

Description: I0

Display default speed and controller firmware version.

I1

Calculate and display ROM checksum (e.g., 12AB).

I2

Check ROM and verify the checksum, displaying OK or

 

ERROR.

I3

Display default speed and controller firmware version.

I4

Display firmware version for data pump (e.g., 94).

I5

Display the board ID: software version, hardware ver-

 

sion, and country ID

I9

Display the country code (e.g., NA Ver. 1).

79