Adding pathways used

Setting Up Infrastructures

4-23

Adding pathways used

Step 1 Highlight the Pathways Used tab.

Step 2 Click the Add button in the Detail area. The Location window appears. Select the first Pathway this backbone is in. Click Accept.

Step 3 Segment, Pathway ID, Pathway Type, and Source are populated on the table.

Step 4 Click Save to save the new information. The Segment column identifies the order in which the backbone uses each of the pathways.

Connecting a Backbone to a Grounding Conductor

See “Grounding” on page 4-23.

If a Grounding Conductor has been set up in the Grounding tab and connected to the current backbone, the Bonding Conductor ID field will be populated in the Backbone Info tab.

Grounding

Grounding runs excess electrical current to ground. Grounding is needed for backbone cables, assets, pathways, and termination hardware. In Cable Management, a busbar must be set up prior to setting up grounding conductors. See Adding Busbars.

Adding Busbars

Busbars have to be set up prior to conductors.

Step 1 Click the space that contains the grounding busbar. Step 2 Select the Grounding category in the List View.

Step 3 Click the Busbars radio button and then the Add button in the List View area.

Step 4 The Location box in the Detail View is populated with the space where the busbar will be set up.

Step 5 Enter the ID in the Busbar ID field.

Step 6 Select the busbar type from the drop-down list in the Busbar Type field. Step 7 Click Save.

TMGB (Telecommunications Main Ground Busbar) is the main busbar that goes directly to the earth ground. The Grounding Conductor ID is the main conductor that connects the TMGB to the ground. The TGB (Telecommunications Ground Busbar)

NOTEis a busbar that will connect to a conductor. Select it from the Busbar Type drop- down list. No other fields appear on the tab when TGB is selected.

MA4000 Expense Management Cable Management User Guide - Issue 1