SmartController 5

Maintenance

5.1Changing the Lamp in the High Power Indicator

The system is equipped with circuitry to detect the potentially dangerous condition of a burned out High Power indicator on the Front Panel. If this lamp is burned out, you cannot enable High Power until the lamp has been replaced. Follow this procedure to replace the High Power indicator bulb. The Adept part number for lamp is 27400-29006.

1.Turn off system power to the SmartController.

2.Disconnect the cable between the Front Panel and the SmartController.

3.Remove the Front Panel from its mounting location.

4.Remove the two screws on the back of the Front Panel.

5.Carefully pull the front cover away from the body of the Front Panel. You will encounter some resistance as there are three plug-type connectors that you need to disconnect as you pull the front cover away from the body.

NOTE: Separate the cover from the body slowly to avoid damaging the two wires that go between the LED and the PC board inside the body. Pull the front cover as straight away as possible. You do not have to disconnect the wires from the PC board, although you can if needed.

6.Locate the lamp body in the center of the back side of the front cover. Turn the lamp body approximately 20° in either direction and then pull straight back.

7.The lamp body is now free. You can remove the old lamp and insert a new one.

8.Replace the lamp body by pushing it straight into the lamp housing receptacle. Make sure the contacts on the lamp body are properly oriented. See Figure 5-1 on page 86.

9.Make sure to reconnect the wires from the LED if you disconnected them earlier. Push the front cover into the body, taking care to align all of the plug-type connectors. Verify that the wires do not get crimped as you reinstall the cover.

10.Replace the two screws on the back of the body.

11.Reinstall the Front Panel in its mounting.

12.Reconnect the cable between the Front Panel and the SmartController.

Adept SmartController User’s Guide, Rev. E

85

Page 85
Image 85
Nortech Systems RS-232/TERM, XUSR, RS-422/485 SmartController Maintenance, Changing the Lamp in the High Power Indicator

RS-422/485, XSYS, XUSR, RS-232/TERM specifications

Nortech Systems offers a comprehensive suite of serial communication solutions, including RS-232/TERM, XUSR, XSYS, and RS-422/485 interfaces. These products are designed to facilitate reliable and high-speed data transmission in various industrial applications, making them essential for connecting devices in automation, telecommunications, and data acquisition systems.

The RS-232/TERM interface is a widely adopted standard for serial communication, known for its simplicity and robustness. It supports point-to-point communication over relatively short distances, typically up to 50 feet. Key features include a maximum baud rate of up to 115.2 kbps, error-checking capabilities, and a straightforward connection process, making it ideal for connecting peripheral devices like printers, modems, and barcode scanners.

Building on the RS-232 standard, the XUSR and XSYS devices offer enhanced functionalities and flexibility. XUSR, for instance, supports not just traditional RS-232 connections, but also protocol conversion for various serial interfaces, facilitating seamless integration of legacy systems with modern networking technologies. It is particularly useful in environments where multiple protocols need to be managed simultaneously.

XSYS is designed for more complex applications and supports advanced communication features such as multi-drop configurations, enabling it to connect multiple devices on a single bus. This makes it suitable for extensive industrial networks where space and wiring complexity need to be minimized. Synchronous and asynchronous data transfer modes ensure that the XSYS is adaptable for both real-time data collection and standard command-response applications.

On the other hand, RS-422/485 interfaces excel in long-distance communication, allowing for data transmission over distances up to 4,000 feet. They are designed for multi-point connections, supporting up to 32 devices on a single bus through differential signaling, which enhances noise immunity. These characteristics make RS-422/485 particularly well-suited for environments with electromagnetic interference, such as factories or subways.

Nortech Systems’ serial communication solutions emphasize reliability, ease of use, and versatility. With their commitment to high performance and user satisfaction, these interfaces provide critical connectivity in today’s increasingly automated and interconnected world. Whether in data centers, manufacturing setups, or remote sensor networks, Nortech's offerings stand out for their reliability, efficiency, and adaptability, ensuring effective data communication across diverse applications.