122Chapter 6 Command line interface
Figure 49 show ports stats pos sectioninterval command output
===========================================================================
POS Section Interval Stats
===========================================================================
PORT | ERRORED SECONDS | SEVERELY ERRORED | CODE VIOLATION SEVERELY ERRORED |
NUM | COUNT (ES) | COUNT (SES) | COUNT |
10/1 | 0 | 0 | 0 | 0 |
10/3 | 900 | 900 | 0 | 0 |
INTERVAL ID = 10
Table 50 describes the information fields for output of the show ports stats pos sectioninterval command.
Table 50 Information fields for output of the show ports stats pos sectioninterval command
Field | Description |
|
|
PORT NUM | Port number. |
|
|
ERRORED SECONDS | Errored Second (ES) is a second with one or more Coding |
COUNT (ES) | Violations (CV) or one or more incoming defects (for |
| example, SEF, LOS, AIS, LOP). |
|
|
SEVERELY ERRORED | Severely Errored Second (SES) is a second with x or more |
COUNT (SES) | CVs, or one or more incoming defects. |
|
|
CODE VIOLATION COUNT | Coding Violations (CV) are Bit Interleaved Parity (BIP) |
errors that are detected in the incoming signal. CV | |
| counters are incremented for each BIP error detected. |
|
|
SEVERELY ERRORED | Severely Errored Framing Second (SEFs) is a second |
FRAMES (SEF) | containing one or more SEF events. |
|
|
INTERVAL ID | Specified interval. |
|
|