Nortel Networks 8683POS manual Show tech command has the following syntax

Models: 8683POS

1 154
Download 154 pages 12.45 Kb
Page 124
Image 124

124Chapter 6 Command line interface

Table 51 Information fields for output of the show ports stats pos sonetmediumtbl command

Field

Description

 

 

PORT NUM

Port number.

 

 

MEDIUM TYPE

Identifies whether a sonet or sdh signal is used across the

 

interface.

 

 

TIME ELAPSED

Number of seconds, including partial seconds, that have

 

elapsed since the beginning of the current measurement

 

period. If the current interval exceeds the maximum value,

 

the agent will return the maximum value.

 

 

VALID INTERVALS

Number of previous 15-minute intervals for which data was

 

collected.

 

 

LINE CODING

Line coding for this interface. The B3ZS and CMI are used

 

for electrical SONET/SDH signals (STS-1 and STS-3). The

 

Non-Return to Zero (NZR) and the Return to Zero are used

 

for optical SONET/SDH signals.

 

 

LINE TYPE

Line type for this interface. The line types are Single Mode

 

fiber or Multi-Mode fiber interfaces.

 

 

CIRCUIT ID

Transmission vendor’s circuit identifier, to facilitate

 

troubleshooting.

 

 

show tech command

The show tech command has the following syntax:

show tech

Figure 51 shows sample output for the show tech command.

209564-A

Page 124
Image 124
Nortel Networks 8683POS manual Show tech command has the following syntax