Freescale Semiconductor, Inc.

Freescale Semiconductor, Inc.

TABLE B1-2. P1 - System Expansion - Interconnect Signals

Pin No.

Signal Name

Attribute

Description

 

 

 

 

 

 

 

 

A26

5V0

P

+5V Supply. Connected to ADS’s 5V plane. Provided as power

 

 

 

supply for external tool. For allowed current draw, see TABLE 7-

A27

 

 

 

 

1. "Off-Board Application Maximum Current Consumption"

 

 

 

on page 66.

A28

 

 

 

 

 

 

 

 

 

A29

 

 

 

 

 

 

 

A30

 

 

 

 

 

 

 

A31

 

 

 

 

 

 

 

A32

 

 

 

 

 

 

 

 

 

 

 

B1

GND

P

Digital Ground. Connected to main GND plane of the ADS.

 

 

 

 

B2

 

 

 

 

 

 

 

B3

 

 

 

 

 

 

 

B4

TSTAT0

I,P.U.

Tool Status (0a:7). This lines may be driven by an external tool to

 

 

 

be read via BCSR2 of the ADS. These lines are pulled-up on the

B5

TSTAT1

 

 

ADS, by 10 Kresistor’s network. See also TABLE 7-1. "Off-

 

 

 

Board Application Maximum Current Consumption" on

B6

TSTAT2

 

 

page 66.

 

 

 

B7

TSTAT3

 

 

 

 

 

 

B8

TSTAT4

 

 

 

 

 

 

B9

TSTAT5

 

 

 

 

 

 

B10

TSTAT6

 

 

 

 

 

 

B11

TSTAT7

 

 

 

 

 

 

B12

TOOLREV0

I,P.U.

Tool Revision (0a:3). This lines should be driven by an external

 

 

 

tool with the Tool Revision Code, to be read via BCSR2 of the

B13

TOOLREV1

 

 

ADS. These lines are pulled-up on the ADS, by 10 Kresistor’s

 

 

 

network. See also TABLE 5-12. "BCSR2 Description" on

B14

TOOLREV2

 

 

page 58.

 

 

 

B15

TOOLREV3

 

 

 

 

 

 

B16

EXTOLI0

I,P.U.

External Tool Identification (0a:3). This lines should be driven by

 

 

 

an external tool with the Tool Identification Code, to be read via

B17

EXTOLI1

 

 

BCSR2 of the ADS. These lines are pulled-up on the ADS, by 10

 

 

 

Kresistor’s network. See also TABLE 5-12. "BCSR2

B18

EXTOLI2

 

 

Description" on page 58.

 

 

 

B19

EXTOLI3

 

 

 

 

 

 

B20

PORSTb

I/O,P.U.

Power-On-Reset. This line is connected to open drain output of

 

 

 

voltage detector device. When power-up is executed this line

 

 

 

asserted low during apr. 800 ms. Off-board power-on-reset may

 

 

 

be provided when this pin is driven by external O.D. (without pull-

 

 

 

up resistor) logic. Failure to do so might result in permanent

 

 

 

damage to the MSC8101 and / or to ADS logic.

 

 

 

 

B-78

MSC8101ADS RevB User’s Manual

MOTOROLA

For More Information On This Product,

Go to: www.freescale.com

Page 79
Image 79
Nortel Networks MSC8101 ADS Gnd, TSTAT0, TSTAT1, TSTAT2 TSTAT3 TSTAT4 TSTAT5, TSTAT6, TSTAT7, TOOLREV0, TOOLREV1, TOOLREV2