TABLE B1-2. P1 - System Expansion - Interconnect Signals

 

Pin No.

Signal Name

Attribute

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C11

IRQ6b

I,P.U.

Interrupt Request 6 . Connected to MSC8101‘s DP6//IRQ6b/

 

 

 

 

 

DACK3 signal. Pulled up on the ADS with a 10 Kresistor. This

 

 

 

 

 

line is shared with the ATM UNI’s interrupt line and therefore,

 

 

 

 

 

when driven by an external tool, MUST be driven with an Open

 

 

 

 

 

Drain gate. Failure to do so may result in permanent damage

 

 

 

 

 

to the MSC8101 or to ADS logic.

 

 

 

 

 

 

 

 

C12

IRQ7b

I.P.U.

Interrupt Request 7 . Connected to MSC8101‘s DP7/IRQ7b/

 

 

 

 

 

DACK4 signal. Pulled up on the ADS with a 10 Kresistor. This

 

 

 

 

 

line is shared with the Fast Ethernet transceiver’s interrupt line

 

 

 

 

 

and therefore, when driven by an external tool, MUST be driven

 

 

 

 

 

with an Open Drain gate. Failure to do so might result in

 

 

 

 

 

permanent damage to the MSC8101 and / or to ADS logic.

 

 

 

 

 

 

 

 

C13

GND

P

Digital Ground. Connected to main GND plane of the ADS.

 

 

 

 

 

 

 

 

C14

EXPD0

I/O, T.S.

Expansion Data (0a:15). This is a double buffered version of the

 

 

 

 

 

PPC bus D(0:15) lines, controlled by on-board logic. These lines

 

 

C15

EXPD1

 

 

 

 

will be driven only if BTOLCS1b or BTOLCS2b are asserted.

 

 

 

 

 

Otherwise they are tristated.

 

 

C16

EXPD2

 

 

 

 

The direction of these lines is determined by buffered BCTL0, in

 

 

 

 

 

 

 

C17

EXPD3

 

function of R~/W.

 

 

 

 

 

 

 

 

C18

EXPD4

 

 

 

 

 

 

 

 

 

 

C19

EXPD5

 

 

 

 

 

 

 

 

 

 

C20

EXPD6

 

 

 

 

 

 

 

 

 

 

C21

EXPD7

 

 

 

 

 

 

 

 

 

 

C22

EXPD8

 

 

 

 

 

 

 

 

 

 

C23

EXPD9

 

 

 

 

 

 

 

 

 

 

C24

EXPD10

 

 

 

 

 

 

 

 

 

 

C25

EXPD11

 

 

 

 

 

 

 

 

 

 

C26

EXPD12

 

 

 

 

 

 

 

 

 

 

C27

EXPD13

 

 

 

 

 

 

 

 

 

 

C28

EXPD14

 

 

 

 

 

 

 

 

 

 

C29

EXPD15

 

 

 

 

 

 

 

 

 

 

C30

IRQ4b

I.P.U.

Interrupt Request 4. Connected to MSC8101‘s DP4/IRQ4b/

 

 

 

 

 

DREQ3 signal. Pulled up on the ADS with a 10 Kresistor. This

 

 

 

 

 

line is shared with the Fast Ethernet transceiver’s interrupt line

 

 

 

 

 

and therefore, when driven by an external tool, MUST be driven

 

 

 

 

 

with an Open Drain gate. Failure to do so might result in

 

 

 

 

 

permanent damage to the MSC8101 and / or to ADS logic.

 

 

 

 

 

 

 

 

C31

IRQ5b

I.P.U.

Interrupt Request 5. Connected to MSC8101‘s DP5/IRQ5b/

 

 

 

 

 

DREQ5 signal. Pulled up on the ADS with a 10 Kresistor. This

 

 

 

 

 

line is shared with the Fast Ethernet transceiver’s interrupt line

 

 

 

 

 

and therefore, when driven by an external tool, MUST be driven

 

 

 

 

 

with an Open Drain gate. Failure to do so might result in

 

 

 

 

 

permanent damage to the MSC8101 and / or to ADS logic.

 

 

 

 

 

 

 

 

 

 

 

 

 

B-80

MSC8101ADS RevB User’s Manual

MOTOROLA