TABLE B1-2. P1 - System Expansion - Interconnect Signals

Pin No.

Signal Name

Attribute

Description

 

 

 

 

 

 

 

 

C32

N.C.

-

Not Connected

 

 

 

 

 

 

 

 

D1

GND

P

Digital Ground. Connected to main GND plane of the ADS.

 

 

 

 

D2

 

 

 

 

 

 

 

D3

 

 

 

 

 

 

 

D4

EXPWE0b

O

Expansion Write Enable (0:1) (L). This are buffered GPCM Write

 

 

 

Enable lines (0:1). They are meant to qualify writes to GPCM

D5

EXPWE1b

 

 

controlled 8/16 data bus width memory devices. This to provide

 

 

 

eased access to various communication transceivers.

 

 

 

EXPWE0b controls EXPD(0:7) while EXPWE1b controls

 

 

 

EXPD(8:15). These lines may also function as UPM controlled

 

 

 

Byte Select Lines, which allow control over almost any type of

 

 

 

memory device.

 

 

 

 

D6

GND

P

Digital Ground. Connected to main GND plane of the ADS.

 

 

 

 

D7

EXPGL0b

O

Expansion General Purpose Lines (0:5). These are buffered

 

 

 

GPL(0:5)b lines which assist UPM control over memory device if

D8

EXPGL1b

 

 

necessary. These are output only signals and therefore, do not

 

 

 

support H/W controlled UPM waits (GPL4 as such UPWAIT).

D9

EXPGL2b

 

 

 

 

 

 

 

D10

EXPGL3b

 

 

 

 

 

 

D11

EXPGL4b

 

 

 

 

 

 

D12

EXPGL5b

 

 

 

 

 

 

D13

GND

P

Digital Ground. Connected to main GND plane of the ADS.

 

 

 

 

D14

V3.3

P

3.3V Power Out. These lines are connected to the main 3.3V

 

 

 

plane of the MSC8101ADS, this, to provide 3.3V power where

 

 

 

necessary for external tool connected. The amount of current

 

 

 

allowed to be drawn from this power bus is found in TABLE 7-1.

 

 

 

"Off-Board Application Maximum Current Consumption" on

 

 

 

page 66.

 

 

 

 

D15

EXPCTL0

O

Expansion Control Line 0. This line is a buffered version of

 

 

 

MSC8101’s BCTL0 (Bus Control Line 0) which serves as R~/W,

 

 

 

provided for expansion board’s use.

 

 

 

 