Product Manual
1 -DIN
RAMP/SOAK PROFILE
CONTROLLER
t ra in e d , e q u ip p e d a n d a u t h o ris e d t o d o s o
HOW TO USE THIS MANUAL
VOLUME INSTALLATION & CONFIGURATION INSTRUCTIONS
VOLUME OPERATING INSTRUCTIONS
INSTALLATION
161 -DIN RAMP/SOAK PROFILE CONTROLLER PRODUCT MANUAL VOLUME
INSTALLATION & CONFIGURATION INSTRUCTIONS
CONTENTS
1.1 UNPACKING PROCEDURE
1.2 PANEL-MOUNTING THE CONTROLLER
1 INSTALLATION
1.3 CONNECTIONS AND WIRING
POWER CONNECTION
POWER
drive,solid state orDC,alarm output
Output 3isused eitherasalarm output
1.3.4 RTD Inputs
1.3.1 Mains Line Input
1.3.2 24V Nominal AC/DC Supply
1.3.3 Thermocouple Input
1.3.8 SSR Drive Outputs
1.3.5 Linear Inputs
1.3.6 Remote Run/Hold Input
1.3.7 Relay Outputs
1.3.11 RS485 Serial Communications Link
1.3.10 DC Outputs
Outp ut 3 Op tion PCB
2 INTERNAL LINKS AND SWITCHES
2.1 REMOVING THE PROFILE CONTROLLER FROM ITS HOUSING
RS485 Com m unic a tions Op tion PC or Re m ote Run/Hold Op tion PCB
Volume
Figure 2-2 Removing the Output 2/Output 3 Option PCBs
S077-2
2.2 REMOVING/REPLACING THE OUTPUT 2/OUTPUT 3 OPTION PCBs
2.4 REPLACING THE INSTRUMENT IN ITS HOUSING
REMOVAL
REPLACEMENT
2.5 SELECTION OF INPUT TYPE AND OUTPUT 1 TYPE
2.5.1 Input Type
Figure 2-4 CPU PCB Relay/SSR Drive/Solid State Output
2.5.2 Primary Output Output 1 Type
2.6 OUTPUT 2 TYPE/OUTPUT 3 TYPE
In Configurat ion Mode
3 CONFIGURATION MODE
3.1 ENTRY INTO CONFIGURATION MODE
Within 30 secs. as 1st key action after power-up
Current Hardware
In Configurat ion Mode
Use these keys also to return to Configuration Mode
Wit h Hardw are Definit ion Code displayed
3.3 OPTION SELECTION
3.4 CONFIGURATION MODE PARAMETERS
Wit h Hardw are Definit ion Code displayed
To display One of three
Parameter
Page
Identifier
Parameter
SIMU LTAN EO U SLY
3.5 EXIT FROM CONFIGURATION MODE
CONTENTS
OPERATING INSTRUCTIONS
BASE MODE
161 -DIN RAMP/SOAK PROFILE CONTROLLER PRODUCT MANUAL VOLUME
3 PROGRAM DEFINITION MODE
APPENDIX A PRODUCT SPECIFICATION APPENDIX B SUMMARY OF DISPLAYS
APPENDIX C RAPID CONTROL FEATURE Alphabetic Index
2 CONTROLLER SET-UP MODE
Shows/enables selection of program Program Number in the range 1
1 BASE MODE
1.1 DISPLAY SEQUENCE - NO PROGRAM RUNNING
Setpoint Strategy = 1, adjustable if SP Lock is OFF
1.5 ABORTING A PROGRAM
1.2 STARTING A PROGRAM
1.3 PUTTING A PROGRAM IN HOLD
1.4 RELEASING A PROGRAM FROM HOLD
Omitted if No. Of Cycles = 1 i.e. No cycling
1.6 DISPLAY SEQUENCE - PROGRAM RUNNING
Omitted if Manual Control is disabled see Section
NOTE All displays are Read Only whilst program is running/held
1.7 RaPID CONTROL FEATURE
1.8 PRE-TUNE FEATURE
Press simultaneously twice in quick succession
Pre-Tune engaged
1.9 ENGAGING BOTH PRE-TUNE AND RaPID FEATURES
1.10 INDICATION OF PRE-TUNE AND RaPID STATUS
RaPID status when
Pre-Tune disengaged
RaPID Status when
Type
1.11 VIEWING THE HARDWARE DEFINITION CODE
O utput Type
Input
1.12 MANUAL CONTROL
Press till front panel shows Press or to change display to
Press till front panel shows
Set upper display to Controller Define lock code
2 CONTROLLER SET-UP MODE
To display Press simultaneously when display shows to display
NOTE Default factory-set lock code is
Lower display =
Output 2 only Outputs 1
Output 1 only
2.1 PARAMETER DETAILS
Function
Adjustment Range
Default
Parameter
Function
Adjustment Range
Default
Parameter
OutputPower
Power
reverse-acting
Process High Alarm
Process High Alarm
direct-acting
ALARM
PROCESS HIGH ALARM
Alarm inactive
Alarm active
To display
2.2 EXIT FROM CONTROLLER SET-UP MODE
When this display shows
Press simultaneously
3 PROGRAM DEFINITION MODE - CREATING/EDITING A PROGRAM
3.1 ENTRY
3.2.1 Basic Guidelines
3.2 CREATING A PROGRAM
NOTE Ramp rate is in units/hour if
3.2.2 Defining Segments - Rate Mode
To make a Soak segment
Move to next segment
To make End segmentan
3.2.3 Defining Segments - Time Mode
To make a Soak segment
Move to next segment
See Subsection See Subsection See Subsection In the range 0
3.2.4 Program Options
In the range 1 to 9999 plus 1 = no cycling
= cycle indefinitely till aborted/held
MANUAL GUARANTEED SOAK
3.2.5 Guaranteed Soak Band
GUARANTEED Guaranteed
ENABLED
3.2.6 Segment Event Status
DISPLAY
DISPLAY
Segment 1 Event Indicator = ON Segment 2 Event Indicator = OFF
Press key
To display
Initial display
Press simultaneously
3.3 DEFAULT VALUES AND ADJUSTMENT RANGES
3.4 EXIT FROM PROGRAM DEFINE MODE
When this display shows
4.3 MESSAGE FORMATS
4 MODBUS COMMUNICATIONS
4.1 INTRODUCTION
4.2 MODBUS FUNCTIONS SUPPORTED
Addr
A. Read Coil Status Read n Bits
01/02
Addr. of
No. of words
B. Read Holding Registers Read n Words 03/04
C. Force Single Coil Write 1 Bit
1st Word
06 B
D. Preset Single Register Write 1 Word
E. Loopback Diagnostic Test
F. Preset Multiple Registers Write n Words 16 B
CRC16
G. Error and Exception Responses
H. CRC16 Calculation
Addr. Func. Exception No
Most significant byte
Normal Bit Order
Reversed Bit Order
REVERSED BIT ORDER USED
A. Bit Parameters Controller Status Byte
4.4 PARAMETER NUMBERS
B. Word Parameters
Controller Parameters
Program Parameters
Parameter
Instrument ID Parameters
Segment Parameters - Program
Segment Parameters - Program
Segment Parameters - Program
Segment Parameters - Program
Parameter
15 14 13 12 11
4.6 PROFILER COMMANDS
4.5 PROFILER STATUS BYTE
Bit Number
UNIVERSAL INPUT General
APPENDIX A PRODUCT SPECIFICATION
Resistance Temperature Detector RTD and DC mV Ranges selectable
REMOTE RUN/HOLD INPUT OPTION
SSR Drive/TTL
OUTPUT
General
Relay
OUTPUT
General
Relay
Solid State
OUTPUT General
Relay
SSR Drive/TTL
LOOP CONTROL
ALARM CONTROL
Performance Under Reference Conditions
PERFORMANCE Reference Conditions
DC Outputs - Accuracy
ENVIRONMENTAL
See PERFORMANCE
PHYSICAL
APPENDIX B SUMMARY OF DISPLAYS
Base Mode Parameters
Controller Set-Up Mode Parameters
Program Define Mode Parameters
Controller Set-Up Mode Parameters Continued
Miscellaneous
Configuration Mode Parameters
SETPOINT CHANGES
AppendixC RaPID Control Feature
START-UP
DISTURBANCE
Indication
The responses to RaPID being engaged are
Pre-Tune
Response
ALPHABETICAL INDEX
Page
Page
Page
Unpacking Procedure
I/1-1
Word Parameters II/4-8