Chapter 4 Adjustments and Settings for Recording — Viewfinder status display

Configuration of status display on viewfinder screenThe status indicators are displayed on the normal screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T C * 1 2 : 3 4 : 5 6 : 2 3

 

1

2

9 9 min

B 9 0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P 2

F U L L

 

I - P AU S E 1 - C L I P

F L UO .

 

 

 

 

 

 

 

 

 

 

 

 

C A C D Z x 2

 

SDI

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F B C

 

1 0 8 0 i

 

 

 

 

 

 

 

AVC-I100

 

 

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

 

 

 

 

P 3 .2K

 

 

 

 

 

 

 

 

 

 

 

 

 

PROXY

ERR

 

 

 

 

 

 

 

L T . BOX

 

 

 

 

 

 

 

 

0 dB

 

E X

8 3%

ND 1

 

 

 

ND 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S E P

1 2 0 1 2 2 3 : 5 9 : 5 9

 

 

 

 

 

 

 

 

 

 

6 0 : 2 4 PN

 

 

 

DR S S PO T

MF 6 0

 

HC

2 = = = = = = = =

 

 

1/ 1 2 3 . 4

F 5 . 6

 

 

Z 6 0

 

HC

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Selecting display items on viewfinder screen

To select display items on the viewfinder screen, switch display [ON]/[OFF] or type at each item on the setting menu [DISPLAY SETUP] screen. For details, refer to “Setting menu basic operations” (page 118).

 

 

DISPLAY SETUP

 

 

 

 

0

 

 

EVF PEAK LEVEL

 

 

 

EVF PEAK FREQ

 

 

LOW

 

EVF TYPE

 

 

 

COLOR

 

EVF COLOR

 

 

 

ON

 

ZEBRA1 DETECT

 

70%

 

ZEBRA2 DETECT

 

85%

 

ZEBRA2

 

 

 

SPOT

 

MARKER

 

 

 

ON

 

 

 

 

 

 

 

PUSH MENU TO RETURN

 

 

 

 

 

 

 

 

Screen display

 

 

 

 

 

35

33

32

30

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T C * 1 2 : 3 4 : 5 6 : 2 3

 

 

 

1

2

 

 

 

9 9 min

 

B 9 0%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

P 2

F U L L

 

 

 

 

 

I - P AU S E

 

1 - C L I P

 

 

F L UO .

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

SDI

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

AC D Z x 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

 

31

 

 

 

 

 

 

F B C

 

4

 

 

 

1 0 8 0 i

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVC-I100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

6

 

 

 

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P 3 .2K

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROXY

ERR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

L T . BOX

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0 dB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ND 1

 

 

 

 

EX

 

 

 

 

 

8 3%

ND 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S E P

1 2 0 1 2 2 3 : 5 9 : 5 9

 

14

 

 

 

6 0 : 2 4 PN

 

 

 

 

 

 

 

 

 

 

 

DR S

 

 

S PO T

 

 

 

MF 6 0

 

 

 

 

 

A.RE

 

C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HC

2 = = = = = = = =

 

 

 

 

 

1/ 1 2 3 . 4

 

 

F 5 . 6

 

 

 

 

 

Z 6 0

 

 

 

 

 

HC

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

16

 

17

 

 

18

19

20

 

 

 

 

 

 

1Time code display

Every time you press the <COUNTER> button, you switch to the following data (or no display).

28

27

26

25

24

23

11

12

22

21

Counter

Counter value (recording mode only)

[TC]

Time code value

 

When operating in the drop frame mode, the “:” (colon) between the second and frame turns into a “.” (dot).

[tc]

Time code value (displayed after frame digit is converted to 24 frames)

 

When operating in the drop frame mode, the “:” (colon) between the second and frame turns into a “.” (dot).

[UB]

User bits value

[FR]

Information of frame rate used for shooting

 

ffFR60I -: 60i interlace mode (60 fields/sec)

 

ffFR60P -: 60P progressive mode (60 frames/sec)

 

ffFR30P -: 30P progressive mode (30 frames/sec)

 

ffFR24P*: 24P progressive mode (24 frames/sec)

 

ffFR24PA*: 24P advance mode (24 frames/sec)

 

ffFR50I -: 50i interlace mode (50 fields/sec)

 

ffFR50P -: 50P progressive mode (50 frames/sec)

 

ffFR25P -: 25P progressive mode (25 frames/sec)

 

*: In the FR24P and FR24PA modes, the sequence information of frame conversion is displayed at the last digit.

– 73 –