Chapter 7 Menu Operations — Menu list

Item

 

Description of settings

 

 

Remark

ZOOM/FOCUS

Selects the unit of zoom and focus values.

 

 

 

 

[NUMBER], [mm/m], [mm/feet], [OFF]

 

 

 

 

ffWhen [mm/m] or [mm/feet] is selected

 

 

 

 

Displayed only when an auto-focus compatible lens is attached.

 

 

 

CARD/BATT

Sets the remaining capacity display for P2 card and battery.

 

 

 

 

[ON], [OFF]

 

 

 

 

P2CARD REMAIN

Selects the type of P2 card remaining capacity display for recording.

 

 

 

 

[ONE‑CARD]

Displays the remaining capacity of the card currently being

 

 

 

 

 

recorded.

 

 

 

 

[TOTAL]

Displays the total remaining capacity of two cards.

 

 

 

OTHER DISPLAY

Sets other information display items.

 

 

 

 

[PARTIAL]

Displays partial information.

 

 

 

 

[ALL]

Displays all information.

 

 

 

 

[OFF]

Does not display.

 

 

 

MENU BACK

Selects whether to make characters stand out by lowering the background

 

 

 

 

transmittance while displaying the setting menu.

 

 

 

 

[ON]

Lowers the background transmittance.

 

 

 

 

[OFF]

Does not lower the background transmittance.

 

 

 

REC COUNTER

Sets counter operation during recording.

 

 

 

 

[TOTAL]

Continues counting by integrating until reset with the <RESET>

 

 

 

 

 

button.

 

 

 

 

[CLIP]

Clears the count value when recording starts, and counts time

 

 

 

 

 

for each shooting.

 

 

 

 

 

 

 

 

indicates factory setting values.

 

 

 

 

 

 

[BATTERY SETUP] screen

 

 

 

 

 

 

 

 

 

 

Item

 

Description of settings

 

 

Remark

EXT DC IN SEL

Sets the type of external DC power.

 

 

 

 

[AC ADAPTER]

AC adaptor

 

 

 

 

[BATTERY]

Battery

 

 

 

BATTERY SELECT

Sets the battery type.

 

 

 

 

[HYTRON50], [HYTRON140], [DIONIC HC], [DIONIC90], [DIONIC160],

 

 

 

 

[ENDURA7], [ENDURA10], [PAG L96e], [TYPE A], [TYPE B]

 

 

 

BATTERY MODE

Sets the near end.

 

 

 

 

[AUTO]

Near end is set automatically with the battery selected with

 

 

 

 

 

[BATTERY SELECT].

 

 

 

 

[MANUAL]

Sets the near end voltage manually.

 

 

 

HYTRON50 NEAR

Sets the near end voltage of [HYTRON50]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.4V] ... [15.0V]

 

 

 

HYTRON140 NEAR

Sets the near end voltage of [HYTRON140]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.1V] ... [15.0V]

 

 

 

DIONIC HC NEAR

Sets the near end voltage of [DIONIC HC]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.1V] ... [15.0V]

 

 

 

DIONIC90 NEAR

Sets the near end voltage of [DIONIC90]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.5V] ... [15.0V]

 

 

 

DIONIC160 NEAR

Sets the near end voltage of [DIONIC160]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.4V] ... [15.0V]

 

 

 

ENDURA7 NEAR

Sets the near end voltage of [ENDURA7]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.4V] ... [15.0V]

 

 

 

ENDURA10 NEAR

Sets the near end voltage of [ENDURA10]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.4V] ... [15.0V]

 

 

 

PAG L96e NEAR

Sets the near end voltage of [PAG L96e]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.1V] ... [15.0V]

 

 

 

TYPE A FULL

Sets the full voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[12.0V] ... [15.5V] ... [17.0V]

 

 

 

TYPE A NEAR

Sets the near end voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.0V] ... [15.0V]

 

 

 

TYPE A END

Sets the end voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [12.7V] ... [15.0V]

 

 

 

TYPE B FULL

Sets the full voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[12.0V] ... [15.6V] ... [17.0V]

 

 

 

TYPE B NEAR

Sets the near end voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [13.4V] ... [15.0V]

 

 

 

TYPE B END

Sets the end voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)

 

 

 

 

[11.0V] ... [12.9V] ... [15.0V]

 

 

 

 

 

 

 

 

indicates factory setting values.

– 130 –