Panasonic AW-HS50N External device control interfaces, LAN connection, Tally/Gpi

Models: AW-HS50N

1 125
Download 125 pages 42.82 Kb
Page 68
Image 68
7. External device control interfaces

7. External device control interfaces

7-1. LAN connection

Use LAN cables to connect the AW-HE50, AW-RP50 and host computer. When connecting the unit directly to another device, use a crossover cable. For network connections via a device such as a hub, use straight cables.

When a hub is not going to be used, ensure that the length of the LAN cable does not exceed 100 meters (328 ft.) (when a CAT5E cable is used).

￿￿For further details on the AW-HE50 and AW-RP50 connections and settings, refer to “2-2-2. Example of connections”.

￿￿For details on the functions available when connection has been made to the host computer, refer to “8. Connections with a computer”.

7-2. TALLY/GPI

The TALLY/GPI connector features five contact input ports

D-sub 15-pin, female, inch thread

for controlling the unit from an external device and seven

 

8

1

open collector output ports for outputting the tally and status

 

 

 

information from the unit to an external device.

 

 

 

 

 

 

 

 

 

15

9

 

 

 

 

 

 

 

Pin

Signal

Input/output

Details of signal

 

 

Operation

no.

 

 

 

 

 

 

 

 

1

TALLY OUT1

Open collector output

Tally output of input image 1

 

A low-level signal is output during tally

2

TALLY OUT2

Open collector output

Tally output of input image 2

 

output.

 

 

 

 

3

TALLY OUT3

Open collector output

Tally output of input image 3

 

 

 

4

TALLY OUT4

Open collector output

Tally output of input image 4

 

 

 

5

TALLY OUT5

Open collector output

Tally output of input image 5

 

 

 

6

ALARM

Open collector output

Fan alarm or power alarm output

A low-level signal is output when trouble

 

 

 

 

 

has occurred.

7

KEY ON

Open collector output

Key combination status output

 

A low level is output during key

 

 

 

 

 

combinations.

8

(RESERVE)

Contact input

(Reserve)

 

 

 

9

NC

 

Not used

 

 

 

10

Tally Disable

Contact input

Tally signal enable/disable

 

This signal is enabled by the contact

 

 

 

 

 

input (and disabled when open).

11

AUTO

Contact input

AUTO button of transition part

 

The signal is made operational by the

12

CUT

Contact input

CUT button of transition part

 

contact input (30 ms or more).

 

 

 

13

KeyON

Contact input

KEY ON button of transition part

 

 

14

PinPON

Contact input

PinP button of transition part

 

 

 

15

GND

Ground

Ground

 

 

 

Example of an open collector output connection

Ensure that the conditions given below are satisfied. Dielectric strength: Max. DC 24 V

Current:

Max. 50 mA

AW-HS50

(Max. voltage: 24 V)

 

 

GPI Out

 

ALARM Out

 

(Max. current: 50 mA)

 

Tally LED

 

Com

Example of a contact input connection

Provide contact inputs.

AW-HS50

+3.3 V

GPI In

Com

68

Page 68
Image 68
Panasonic AW-HS50N External device control interfaces, LAN connection, Tally/Gpi, D-sub 15-pin,female, inch thread