3. Basic operations

3-1-4. Selecting the bus mode

The bus mode can be set by the following menu operations.

[13]Operation Menu

5.Bus Mode

A/B bus:

When the slide lever is at side A, the signals selected by the A bus are output as PGM images.

When the slide lever is at side B, the signals selected by the B bus are output as PGM images.

PGM (A)/PST (B):

Using a flip-flop system, the signals selected by the A bus are always output as PGM images, and the signals selected by the B bus are always output as PST images.

PGM (B)/PST (A):

Using a flip-flop system, the signals selected by the B bus are always output as PGM images, and the signals selected by the A bus are always output as PST images.

3-1-5. Selecting the transition type

Use the MIX button and WIPE button to select the background transition mode.

3-1-6. Manual transitions

Operate the slide lever to execute transitions manually. If the slide lever is moved while an auto transition is executed, operation will switch to manual as soon as the position of the slide lever has gone beyond the amount of the transition which has been executed.

The bus tally indicators on the left of the lever show the program bus output statuses.

When only indicator A is lighted:

A bus output

When both indicators A and B are lighted:

Transition underway

When only indicator B is lighted:

B bus output

<Setting the slide lever function>

[13]Operation Menu

7.Slide Lever

Any of the following materials for which the transition is to be executed can be set by operating the slide lever.

BKGD, Key, PinP, NoAsign