How to use network functions (continued)
zMail with the contents shown below is sent when the
=== Panasonic projector | report(CONFIGURE) === |
|
|
|
| ||||||||||
Projector Type |
|
| : DZ12000 |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
| ||||||||
TEMPERATURE WARNING SETUP |
|
|
|
|
|
|
|
|
|
| |||||
MINIMUM TIME |
|
|
| at | [ | 60] minutes interval |
|
|
| ||||||
INPUT AIR TEMPERATURE | Over | [ | 35degC / 95degF ] |
|
|
|
| ||||||||
OUTPUT AIR TEMPERATURE | Over | [ | 60degC / 140degF ] |
|
|
| |||||||||
ERROR |
|
|
|
| [ | ON | ] |
|
|
|
|
|
|
|
|
LAMP1 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 200] H |
|
|
| |||||
LAMP1 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 100] H |
|
|
| |||||
LAMP2 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 200] H |
|
|
| |||||
LAMP2 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 100] H |
|
|
| |||||
LAMP3 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 200] H |
|
|
| |||||
LAMP3 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 100] H |
|
|
| |||||
LAMP4 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 200] H |
|
|
| |||||
LAMP4 RUNTIME |
|
|
| [ | OFF ] |
| at REMAIN [ 100] H |
|
|
| |||||
INPUT AIR TEMPERATURE | [ | OFF ] |
|
|
|
|
|
|
|
| |||||
OUTPUT AIR TEMPERATURE | [ | OFF ] |
|
|
|
|
|
|
|
| |||||
PERIODIC REPORT |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Sunday | [ ON | ] | Monday |
| [ | ON | ] | Tuesday | [ ON | ] Wednesday | [ ON ] | ||||
Thursday [ ON | ] | Friday |
| [ | ON | ] | Saturday | [ ON | ] |
|
| ||||
00:00 | [ ON | ] |
| 01:00 | [ | ON | ] |
| 02:00 | [ ON | ] | 03:00 | [ ON | ] | |
04:00 | [ ON | ] |
| 05:00 | [ | ON | ] |
| 06:00 | [ ON | ] | 07:00 | [ ON | ] | |
08:00 | [ ON | ] |
| 09:00 | [ | ON | ] |
| 10:00 | [ ON | ] | 11:00 | [ ON | ] | |
12:00 | [ ON | ] |
| 13:00 | [ | ON | ] |
| 14:00 | [ ON | ] | 15:00 | [ ON | ] | |
16:00 | [ ON | ] |
| 17:00 | [ | ON | ] |
| 18:00 | [ ON | ] | 19:00 | [ ON | ] | |
20:00 | [ ON | ] |
| 21:00 | [ | ON | ] |
| 22:00 | [ ON | ] | 23:00 | [ ON | ] | |
check system |
|
|
|
|
|
|
|
|
|
| |||||
MAIN CPU BUS |
|
|
|
| [ |
| OK |
| ] |
|
|
|
|
| |
FAN |
|
|
|
|
| [ |
| OK |
| ] |
|
|
|
|
|
OPTICS MODULE TEMPERATURE | [ |
| OK |
| ] |
|
|
|
|
| |||||
INPUT AIR TEMPERATURE |
| [ |
| OK |
| ] |
|
|
|
|
| ||||
OUTPUT AIR TEMPERATURE |
| [ |
| OK |
| ] |
|
|
|
|
| ||||
LAMP1 REMAIN TIME |
|
| [ |
| OK |
| ] |
|
|
|
|
| |||
LAMP2 REMAIN TIME |
|
| [ |
| OK |
| ] |
|
|
|
|
| |||
LAMP3 REMAIN TIME |
|
| [ |
| OK |
| ] |
|
|
|
|
| |||
LAMP4 REMAIN TIME |
|
| [ |
| OK |
| ] |
|
|
|
|
|
zMail with the contents shown below is sent when an error has occurred.
=== Panasonic projector report(ERROR) ===
Projector Type |
| : DZ12000 |
|
| ||
|
|
|
| |||
MAIN CPU BUS |
|
| [ | OK | ] |
|
FAN |
|
| [ | OK | ] |
|
OPTICS MODULE TEMPERATURE | [ | OK | ] |
| ||
INPUT AIR TEMPERATURE |
| [ | OK | ] |
| |
OUTPUT AIR TEMPERATURE |
| [ | OK | ] |
| |
LAMP1 REMAIN TIME |
|
| [ | OK | ] |
|
LAMP2 REMAIN TIME |
|
| [ | OK | ] |
|
LAMP3 REMAIN TIME |
|
| [ | OK | ] |
|
LAMP4 REMAIN TIME |
|
| [ | OK | ] |
|
LAMP1 STATUS |
|
| [ | OK | ] |
|
LAMP2 STATUS |
|
| [ | OK | ] |
|
LAMP3 STATUS |
|
| [ | OK | ] |
|
LAMP4 STATUS |
|
| [ | OK | ] |
|
[ | OK | ] |
| |||
| [ | OK | ] |
| ||
DIRTY AIR FILTER |
|
| [ FAILED | ] |
| |
AIR FILTER CLEANER UNIT | [ | OK | ] |
| ||
OPTICS MODULE TEMP.SENSOR | [ | OK | ] |
| ||
INPUT AIR TEMP.SENSOR |
| [ | OK | ] |
| |
OUTPUT AIR TEMP.SENSOR |
| [ | OK | ] |
| |
BATTERY |
|
| [ | OK | ] |
|
CLOGGED FILTER SENSOR |
| [ | OK | ] |
| |
LENS SHIFT |
|
| [ | OK | ] |
|
COVER OPEN |
|
| [ | OK | ] |
|
AC POWER |
|
| [ | OK | ] |
|
(Error code 00 00 00 00 00 | 00 00 00 | 00 00 00 10 00 00 00 00) | ||||
Input air temperature |
| : 27 degC / | 80 degF | |||
Optics module temperature | : 34 degC / | 93 degF | ||||
Output air temperature |
| : 33 degC / | 91 degF | |||
SET RUNTIME | 12 | H |
|
|
|
|
POWER ON | 12 | times |
|
|
|
|
LAMP1 ON | 419 | times |
|
|
|
|
LAMP1 HIGH | 314 | H |
|
|
|
|
LAMP2 ON | 363 | times |
|
|
|
|
LAMP2 HIGH | 252 | H |
|
|
|
|