ENGLISH
65
Basic Operation

Press ENTER.2.

The “BLANKING” adjustment screen will be
displayed.
BLANKING
UPPER
LOWER
0
0

Press ▲▼ to select the desired 3.

item for adjustment.

Press ◄► to adjust blanking.4.

The adjustment value for the PT-D12000U can
be changed within a range of 0 to 525 vertically
and 0 to 700 horizontally.
The adjustment value for the PT-DZ12000U can
be changed within a range of 0 to 600 vertically
and 0 to 960 horizontally.
When correcting the upper blanking of the
screen (top)
Press button to
move the blanking zone
upward; button to
downward.
When correcting the lower blanking of the
screen (bottom)
Press button to
move the blanking zone
upward; button to
downward.
When correcting the left hand blanking of
the screen (left)
Press button to move
the blanking zone to the
right; button to the
left.
When correcting the right hand blanking of
the screen (right)
Press button to move
the blanking zone to the
right; button to the
left.
Adjusting the input resolution
Input resolution adjustment achieves the best image
when the screen flickers or halo is observed around
the contour. Set the values appropriately for the signal
resolution that is being used.

Press ▲▼ to select “INPUT 1.

RESOLUTION”.

BLANKING
INPUT RESOLUTION
CLAMP POSITION

Press ENTER.2.

The “INPUT RESOLUTION” screen will be
displayed.
INPUT RESOLUTION
TOTAL DOTS
DISPLAY DOTS
1344
1024

Press ▲▼ to select “TOTAL 3.

DOTS”, “DISPLAY DOTS”,

“TOTAL LINES” or “DISPLAY

LINES”, and the press ◄► to

adjust it.

Each item automatically displays a value in
response to the type of the input signal. If
vertical stripes appear on the screen or the
image is partly missing, increase or decrease
the displayed value while observing the screen
to achieve the optimal value.
Note
The abovementioned vertical stripes will not appear
on the screen when all signals are input.
The picture may be distorted during the adjusting
operation, but this is not a fault.
The input resolution can be adjusted only when
RGB signal input is applied with RGB1 and RGB2
IN.
Adjusting the clamp position
Use the clamp position adjustment to achieve the
optimal value when dark areas of the image are
crushed or displayed in green.

Press ▲▼ to select “CLAMP 1.

POSITION”.

INPUT RESOLUTION
CLAMP POSITION
EDGE BLENDING OFF