Lamp select

This lets you switch the four light source lamps to one of four brightnesses in accordance with the operating conditions and purpose of use.

1. Press ▲▼ to select “LAMP SELECT”.

 

DIRECTION

HORIZONTAL

 

 

 

LAMP SELECT

QUAD

 

 

 

LAMP RELAY

OFF

 

 

 

 

 

 

 

2.Press ◄► to switch “LAMP SELECT”.

The setting will change as follows each time ◄► is pressed.

 

 

 

 

 

TRIPLE

 

QUAD

 

 

 

 

 

DUAL

 

L1

 

 

 

 

 

SINGLE

 

L2

 

 

 

 

 

L2/L3/L4

 

L3

 

 

 

 

 

L1/L3/L4

 

L4

 

 

 

 

 

L1/L2/L4

 

L1/L4

 

 

 

 

 

L1/L2/L3

 

L2/L3

 

 

 

 

 

“QUAD” : The four lamps illuminate.

“L1” : One lamp illuminates. (Lamp unit 1 takes priority.)

“L2” : One lamp illuminates. (Lamp unit 2 takes priority.)

“L3” : One lamp illuminates. (Lamp unit 3 takes priority.)

“L4” : One lamp illuminates. (Lamp unit 4 takes priority.)

“L1/L4” : Two lamps illuminate. (Lamp unit 1 and 4 take priority.)

“L2/L3” : Two lamps illuminate. (Lamp unit 2 and 3 take priority.)

“L1/L2/L3” : Three lamps illuminate. (Lamp units 1, 2 and 3 take priority.)

“L1/L2/L4” : Three lamps illuminate. (Lamp units 1, 2 and 4 take priority.)

“L1/L3/L4” : Three lamps illuminate. (Lamp units 1, 3 and 4 take priority.)

“L2/L3/L4” : Three lamps illuminate. (Lamp units 2, 3 and 4 take priority.)

“SINGLE” : One of the lamps illuminates.

(The lamp unit with the shortest operating time is selected automatically.)

“DUAL” : Two lamps illuminate.

(The lamp units with the shortest operating time out of lamp units 1 and 4 or 2 and 3 are selected automatically.)

“TRIPLE” : Three lamps illuminate.

(The lamp unit with the shortest operating time is selected automatically.)

3. Press ENTER.

Note

For settings other than “QUAD”, any lamp which is malfunctioning or which has a cumulative operating time that exceeds 2 000 hours will be turned off and the other lamps will be turned on. If “QUAD” is selected, any lamp which is malfunctioning or which has a cumulative operating time that exceeds 2 000 hours will be turned off and only the lamps which have a cumulative operating time of less than 2 000 hours will be turned on. In addition, if the cumulative operating times for all lamps exceed

2 000 hours, the projector will switch to standby mode.

Lamp units which are not turned on should still be installed to the projector.

When it is time to replace the lamp, the number of the lamps that illuminate will be greater than the specified number of lamps in order to prevent the luminance from dropping.

The characters in the lamp selection menu will become green when they are selected. Furthermore, the characters may flash depending on the condition of the lamps.

Yellow:

An error has occurred with the

 

illumination of one or more of the lamps

White:

Unselected item

Red:

Lamp where an illumination error has

 

occurred

Special Features

ENGLISH 79

Page 79
Image 79
Panasonic PT-DZ12000U, PT-D12000U manual Lamp select, Press to select Lamp Select, Press to switch Lamp Select