ENGLISH
59
Basic Operation
ET-MD100SD4:
When single link SDI signals
Select from AUTO YCbCr, 1 080/60i, 1 035/60i,
720/60p, 1 080/24p, 1 080/50i, 1 080/30p,
1 080/25p, 1 080/24sF, 720/50p, 480i, and 576i.
When dual link SDI signals
Select from AUTO RGB, AUTO X’Y’Z’,
1 920/24p/RGB, 2 048/24p/RGB, 2 048/24p/XYZ,
1 920/24sF/RGB, 2 048/24sF/RGB, 2 048/24sF/
XYZ, 1 920/25p/RGB, 1 920/30p/RGB, 1 920/50i/
RGB, and 1 920/60i/RGB.
Note
Press the DEFAULT button to return to AUTO
YCbCr or AUTO RGB.
“AUTO RGB” automatically selects from 1 920/24p/
RGB, 2 048/24p/RGB, 1 920/24sF/RGB,
2 048/24sF/RGB, 1 920/25p/RGB, 1 920/30p/RGB,
1 920/50i/RGB, and 1 920/60i/RGB. “AUTO X’Y’Z’”
automatically selects from 2 048/24p/XYZ and
2 048/24sF/XYZ.
To display pictures complying with the sRGB standard
sRGB is the international color reproduction standard
(IEC61966-2-1) established by IEC (International
Electrotechnical Commission).
To reproduce colors more faithfully in compliance
with the sRGB standard, perform the following setting
procedure.
Set “COLOR MATCHING” 1.
adjustment to “OFF”. (p. 70)
Display the “PICTURE” screen. 2.
(p. 54)
Press ▲▼ to select “PICTURE 3.
MODE”.
PICTURE
PICTURE MODE
CONTRAST
NATURAL
0
Press ◄► to select “NATURAL”.4.
Press ▲▼ to select “COLOR”.5.
BRIGHTNESS
COLOR
TINT
0
0
0
Press DEFAULT on the remote 6.
control to restore the factory
default.
Follow the same procedure 7.
(steps 5-6) to restore the factory
default for “TINT”, “COLOR
TEMPERATURE” and “GAMMA”.
Note
sRGB is only enable when RGB signals are being
input.