Troubleshooting

Replacing the Lithium Battery

During the initial self test, when the power is turn “On”, the machine will evaluate the condition of the back up battery. If the battery is weak or fully discharged, the following message will be shown on the display.

REPLACE BATTERY

INFO. CODE=026

To replace the battery, follow the procedure below:

1

2

 

3

2

 

3

2

 

 

1

4

 

(1)Turn the Power Switch to the “O” (OFF) position.

(2)Open the ADF Door.

(3)Remove the Battery together with the Battery Holder.

Caution: Dispose the Lithium battery properly and keep it away from small children.

Replace the Lithium Battery. (Order No.: CR2032)

Caution: When replacing the battery make sure to observe the polarity to avoid damage to the machine.

(1)Install the Battery Holder into the machine.

(2)Close the ADF Door.

(3)Turn the Power Switch to the “I” (ON) position.

If the clock is flashing on the LCD Display, follow the procedure on page 26 to reset the clock.

NOTE

1. The service life of the battery is approximately 1 year when the machine is turned “Off”.