Connection with the Camera Sites

Connect cameras (or camera site equipment) data mul- tiplexed type to the CAMERA IN connectors 1 through 4 on the rear of the video multiplexer.

Note: Make sure that the cable length between the camera site and the WJ-FS616C video multiplexer is less than 900 m (3 000 ft) when using RG-59/U, BELDEN 9259 or equivalent cables.

Connect none multiplexed type cameras to the CAM- ERA IN connectors 5 through 16.

Note: If you need to change input channels from the none multiplexed type to multiplexed, install the WV-PB6164 Data Multiplex Boards for the corre- sponding channels inside the video multiplexer. For installations, see page 12.

For cameras equipped with RS-485 communication facility, connect the RS-485 cable as follows.

Note: If you use cables assembled from locally pro- cured materials, it is important that only high quality, data grade cable, suitable for RS-485 communica- tion (shielded 2-wire twisted pair cable) is used, BELDEN 9406 or equivalent.

Low grade cable will result in unstable operation of the system.

Check the settings of the camera addresses when using cameras capable of RS-485 communication. Operations from the multiplexer will not work if the cam- era addresses are set improperly.

Do not use addresses other than 1 through 16 for individual cameras (“17” is not allowed.)

Do not set the same address for more than one camera in an RS-485 chain.

AUX

Alarm

 

 

RS485

 

 

16

15

14

13

5

4

3

2

1

 

 

 

 

 

 

CAMERA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN

 

 

 

 

 

 

 

 

A

B

G

A

B

G

CAMERA

 

 

 

 

 

 

 

 

T

 

N

R

 

N

 

 

 

 

 

 

 

 

 

D

 

D

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

14

13

5

4

3

2

1

 

 

 

 

 

 

 

 

Video Multiplexer WJ-FS616C

 

 

17

Page 17
Image 17
Panasonic WJ-FS616C manual Connection with the Camera Sites