Alarm Reset

Manual Reset

When an alarm is activated, the ALARM indicator blinks. The indicator keeps blinking until all alarms are cleared by pressing the [ALARM RESET] button.

The blinking or lit indicator goes off.

ALARM

RESET

Example of Using Multiscreen 2 Monitor

The figure below shows an example of how alarm is dis- played when a Multiscreen 2 Monitor is connected to the REC OUT connector.

(selects ALM-LINK for ALM MODE-MLT in the ALARM SETUP menu.)

Multiscreen 2 Monitor

Multiscreen Monitor

CH1 Alarmed

 

 

CH1

 

 

 

 

 

 

Auto Reset

The alarm is automatically reset after the programmed alarm output time has elapsed or the lost video signal has been recovered.

CH2 - CH4 Alarmed

CH5 Alarmed

CH1 CH2

CH3 CH4

CH1 CH2

CH3 CH4

CH5

The ALARM indicator changes from blinking to a steady light.

Pressing the [ALARM RESET] button will clear the alarm and switch the indicator off.

External Reset

The alarm is reset by a recover signal received from the external equipment at pin 8 of the ALARM/REMOTE port located on the rear of the video multiplexer.

CH6 - CH8 Alarmed

CH9 Alarmed

CH1 CH2

CH3 CH4

CH9 CH2

CH3 CH4

CH5 CH6

CH7 CH7

CH5

CH6

 

 

 

 

 

 

 

SequenceDisplay

CH7

CH8

 

 

 

 

 

 

 

 

 

 

The ALARM indicator goes off.

CH9 CH10

CH10 - CH13

Alarmed

CH11 CH12

CH13

CH6

 

 

CH7

CH8

PC Command Reset

The alarm is reset by an OAL command from a personal computer, either manually or automatically depending on the Alarm Reset parameter selected.

Refer to the command table on page 78.

In these reset functions, the reset signal is output from pin 27 of the ALARM/REMOTE port.

When alarm is activated, the image of the alarmed cam- era is displayed in single spot mode on the multiscreen 2 monitor.

From the second alarm on, the images of the alarmed cameras are displayed in quad mode on the multi- screen 2 monitor in the order of upper left to lower right segment.

The fifth alarm activated is displayed in single spot mode on the multiscreen monitor, while the previous four alarms remain displayed in quad mode on the mul- tiscreen 2 monitor.

From the sixth alarm on, the images of the alarmed cameras are displayed in quad mode on the multi- screen monitor.

From the ninth alarm on, the images of the alarmed cameras on the multiscreen 2 monitor are overwritten in the order of upper left to lower right segment.

Then the overwritten and previous images are dis- played alternately.

From the thirteenth alarm on, the images of the alarmed cameras on the multiscreen monitor are overwritten in the order of upper left to lower right segment.

Then that overwritten and previous images are dis- played alternately.