4.Select the preset position number to be assigned in the PRE column by pressing the - or + button.

5.Repeat steps 2 to 4 above to assign other terminal numbers.

Note: The same channel number can be assigned to multiple alarm terminals.

In this case, different preset positions can be assigned, but when alarm occurs at these positions, the camera movHes to the preset position where the most recent alarm occurred.

6.Press the [SET UP/ESC] button to execute the settings and returns to the previous SYSTEM SETUP menu.

Playback Mode

This item lets you select the ID code for playback of record- ed videotape.

1.Move the cursor to the PLAYBACK MODE parameter in the SYSTEM SETUP menu.

2.Select either FIELD or FS10.

FIELD: Normally set to this position.

FS10: Enables playback of the videotape that is record- ed with the WJ-FS10.

The factory default setting is FIELD.

Data Mode

This item lets you select an external controller from the DATA port.

1.Move the cursor to the DATA MODE parameter in the SYSTEM SETUP menu.

2.Select either CU or PC.

CU: Enables control from the specified System Controller.

PC: Enables control from a PC.

The factory default setting is CU.

RS-232C Mode

This item lets you select the RS-232C port for control of the VCR, or for external control of the system from a PC.

1.Move the cursor to the RS-232C MODE parameter in the SYSTEM SETUP menu.

2.Select either VCR or PC.

VCR: Enables use as VCR control port.

PC: Enables use as external control port from a PC.

The factory default setting is VCR.

Note: Be sure to select PC in this menu if you plan to use the REMOTE OUT connector for control- ling the VCR.

Communication Port Setup

This item lets you set the parameters for communication between the ports and the connected appliances.

1.Move the cursor to COM PORT SETUP in the SYSTEM menu, then press the [HOME/SET] button.

The COM PORT SETUP table shown in the figure appears on the monitor screen.

 

COM PORT SETUP

 

 

RS-232C

DATA

RS-485

DELAY

 

OFF

 

OFF

OFF

BAUD RATE

9600

9600

19200

WAIT TIME

 

OFF

100

OFF

DATA BIT

7

 

8

8

PARITY

 

ODD

EVEN

NONE

STOP BIT

1

 

1

1

XON/XOFF

-

 

OFF

OFF

FULL/HALF

-

 

-

FULL

2.Move the cursor to the port column you want to edit by pressing the C, D, A or B button.

The table indicates the factory default settings.

3.Select the desired delay time for DELAY by pressing the - or + button.

OFF 10 20 40 60 80 100

4.Select the desired transmission speed (bits per sec- ond) for BAUD RATE by pressing the - or + button.

1 200 2 400 4 800 9 600 19 200

42

Page 42
Image 42
Panasonic WJ-FS616C manual Playback Mode, Data Mode, RS-232C Mode, Communication Port Setup