Cable Compensation/VD2/Data

This item lets you select the optimum setting for the cable- loss compensator and whether to supply the VD2 (sync) signal or control data to the camera.

Note: These settings will work only for the input channels that have the multiplex feature with the Data Multiplex Board WV-BP6164 installed. The boards are installed for input channels 1 through 4 at the factory. You can install boards for other channels. For installations, see page 12.

1.Press the [FUNCTION] button while the SYSTEMSETUP menu (1 of 2) is displayed on the monitor screen.

The next page of the menu appears on the screen.

2.Move the cursor to CABLE COMP/VD2/DATA SETUP in the SYSTEM MENU, then press the [HOME/SET] button. The CABLE COMP/VD2/DATA SETUP table shown in the figure appears on the monitor screen.

CABLE COMP/VD2/DATA SETUP 1 OF 2

CAM CABLE VD2 DATA

1CH

S

ON

ON

2CH

S

ON

ON

3CH

S

ON

ON

4CH

S

ON

ON

5CH

S

OFF

OFF

6CH

S

OFF

OFF

7CH

S

OFF

OFF

8CH

S

OFF

OFF

5.Select either ON or OFF in the VD2 column by pressing the - or + button.

Note: Select ON for a camera with VD2 capability, oth- erwise select OFF.

6.Select one of the parameters shown below in the DATA column by pressing the - or + button.

ON: Communicates with the camera site by multiplexed data.

1-16:Communicate with the camera site by RS-485. This number indicates the unit address of the selected camera.

OFF: Disables communication with the camera site.

6.Repeat steps 3 to 6 above to edit other channels.

Press the [FUNCTION] button to display the next page of the table, then press this button again to return to the previous page.

7.After finishing the settings, press the [SET UP/ESC] but- ton to execute the settings and returns to the previous SYSTEM SETUP menu.

Note: Installation of the WV-PB6164 Data Multiplex Boards is required for controlling more than 4 cam- eras.

CABLE COMP/VD2/DATA SETUP 2 OF 2

CAM CABLE VD2 DATA

9CH

S

OFF

OFF

10CH

S

OFF

OFF

11CH

S

OFF

OFF

12CH

S

OFF

OFF

13CH

S

OFF

OFF

14CH

S

OFF

OFF

15CH

S

OFF

OFF

16CH

S

OFF

OFF

3.Move the cursor to the columns you want to edit for the channel by pressing the C, D, A or B button.

4.Select one of the parameters shown below in the CABLE column by pressing the - or + button.

This item lets you select a suitable cable-loss compen- sator corresponding with the cable length.

S:Up to 400 m (1 300 ft)

M:400 m (1 300 ft) to 700 m (2 300 ft)

L:700 m (2 300 ft) to 900 m (3 000 ft)

(Using the RG-59/U, BELDEN 9259 or equivalent cable)

Note: Set CABLE to S if no camera is connected to the channel.

Alarm Terminal Setup

This item lets you designate the alarm input from the ALARM/REMOTE port located on the rear of the multiplexer.

1.Move the cursor to ALM TERMINAL SETUP in the SYS- TEM SETUP menu, then press the [HOME/SET] button. The ALARM TERMINAL SETUP table shown in the fig- ure appears on the monitor screen.

 

ALARM

TERMINAL SETUP

 

NO.

CAM

PRE

NO.

CAM

PRE

1

1CH

 

-

9

9CH

-

2

2CH

-

10

10CH

-

3

3CH

-

11

11CH

-

4

4CH

-

12

12CH

-

5

5CH

-

13

13CH

-

6

6CH

-

14

14CH

-

7

7CH

-

15

15CH

-

8

8CH

-

16

16CH

-

2.Move the cursor to the columns you want to edit for the terminal number by pressing the C, D, A or B button.

3.Select the channel number to be assigned in the CAM column by pressing the - or + button.

Note: Channel numbers can also be input directly with the camera number buttons.

41