Alarm Mode on the Multiscreen Monitor

This item lets you select the mode for displaying an alarm on the multiscreen monitor.

1.Move the cursor to the ALM MODE-MLT parameter.

2.Select the desired mode.

ALM-LINK:Switches screen to the camera image of the corresponding channel with an alarm title super- imposed.

ALM-IND:Retains the camera image currently select- ed.

An alarm title appears overlapped on the camera image.

If no camera is currently selected the alarm title does not appear.

The factory default setting is ALM-IND.

3.When ALM-LINK is selected for the parameter, then the cursor can be moved to the DWELL TIME parameter.

Dwell Time for Alarm Sequence

If more than one alarm is activated when ALM-LINK is selected, the respective camera images are displayed in quad mode on the multiscreen monitor.

From the fifth alarm on, the images are displayed sequen- tially in quad mode.

This item lets you set the dwell time for the alarm sequence.

1.Move the cursor to the DWELL TIME parameter.

2.Select the desired dwell time.

1SEC - 30SEC: Selects a dwell time between 1 second and 30 seconds.

The factory default setting is 2 SEC.

Alarm Mode on the Spot Monitor

This item lets you select the mode for displaying an alarm on the spot monitor.

1.Move the cursor to the ALM MODE-SPT parameter.

2.Select the desired mode.

ALM-SPOT:The camera image that has activated the alarm is displayed in single spot mode.

If multiple alarms are activated, the monitor displays the camera image that has activated the alarm most recent.

ALM-IGNORE:Ignores alarms activation and retains the camera image currently selected.

The factory default setting is ALM-SPOT.

Dynamic Recording

In this mode, the camera image of the channel on which the alarm was activated is recorded preferentially over other video inputs.

This item lets you enable or disable dynamic recording mode for recording on videotape.

1.Move the cursor to the DYNAMIC REC parameter.

2.Select either ON or OFF.

ON: Enables dynamic recording.

OFF: Disables dynamic recording.

The factory default setting is OFF

Alarm Recording Mode

This item lets you select the mode for recording an alarm. Refer to Recording Mode Setup on page 33 for further details.

1.Move the cursor to the ALM REC MODE parameter.

2.Select the desired recording mode.

MODE 0: Normal Recording

MODE 1-8:Time lapse mode without camera switching pulse.

MODE 9: Time lapse mode with camera switching pulse.

The factory default setting is MODE 0.

3.After completed the setting, press the [SET UP/ESC] button to return to the previous WJ-FS616C SETUP

28

Page 28
Image 28
Panasonic WJ-FS616C manual Alarm Mode on the Multiscreen Monitor, Alarm Mode on the Spot Monitor, Dynamic Recording