Contact Insert
Up A
Approx.
3 mm (0.1 inch)
Insert the wire until A position
and clamp the contacts.
Wire
Note: When powered up, the unit performs a self-
check (including one panning, tilting, zooming
and focusing operation).
24 V AC Power Supply Connection
Prepare the individual conductors for clamping. Use
MOLEX band tool part number 57027-5000 (for UL-
Style Cable UL1015) or 57026-5000 (for UL-Style
UL1007) for clamping the contacts.
After clamping the contacts, push them into the proper
holes in the accessory connector of this camera until
they snap in place.
Cautions:
Shrinking the cable-entry seal is a one-time proce-
dure. Do not shrink the cable-entry seal until it has
been ascertained that the unit is functioning.
CONNECT THIS TO 24V AC CLASS 2 POWER
SUPPLY ONLY.
How to Assemble the Cable with the Accessory
Connector
Strip back the cable jacket approx. 3 mm (0.1 inch) and
separate the individual conductors.
Copper wire size
(AWG)
-12-
CONNECTIONS
Precautions
The following connections should be made by qualified service personnel or system installers in accordance with
all local codes.
See the reverse side of the cover page for mains lead connection.
The coaxial cable length (RG-6/U, 5C-2V) for the connection is up to 1 200
meters (4 000 ft.)
To VIDEO IN
(CAMERA IN)
Video output
24 V AC
BNC plug
Coaxial cable
Ethernet cable
Data port
BNC plug
Alarm in
Alarm out
To sensors
To indicators
24 V AC cable
Adapter
75

Recommended wire gauge sizes for 24 V AC line

#24
(0.22mm2)
Length
of cable
(approx.)
(m)
(ft)
#22
(0.33mm2)
#20
(0.52mm2)
#18
(0.83mm2)
20 30 45
65 100 160 260

Accessory Connector Information

Pin no. Power source
1
2
3
4
24 V AC LIVE
24 V AC NEUTRAL
Ground
Not use

1

3

2

4

Contact
Up Wire