CONNECTIONS
Precautions
•The following connections should be made by qualified service personnel or system installers in accordance with all local codes.
•See the reverse side of the cover page for mains lead connection.
Adapter
24 V AC
Data port
24 V AC cable |
|
Ethernet cable |
|
Coaxial cable | To VIDEO IN |
| (CAMERA IN) |
Video output | Alarm in | BNC plug | BNC plug |
|
|
|
To sensors
To indicators
Alarm out
✻The coaxial cable length
Note: When powered up, the unit performs a self- check (including one panning, tilting, zooming and focusing operation).
• 24 V AC Power Supply Connection
Recommended wire gauge sizes for 24 V AC line
Copper wire size | #24 | #22 | #20 | #18 | ||
(AWG) |
| (0.22mm2) | (0.33mm2) | (0.52mm2) | (0.83mm2) | |
|
|
|
|
|
| |
Length | (m) | 20 | 30 | 45 | 75 | |
of cable |
|
|
|
|
| |
(ft) | 65 | 100 | 160 | 260 | ||
(approx.) | ||||||
|
|
|
|
|
|
Accessory Connector Information
Pin no. | Power source |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 | 24 V AC LIVE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 | 24 V AC NEUTRAL | 4 |
|
| 3 | |||||
3 | Ground |
|
|
|
|
|
|
|
|
|
2 |
| 1 | ||||||||
4 | Not use |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
How to Assemble the Cable with the Accessory Connector
Strip back the cable jacket approx. 3 mm (0.1 inch) and separate the individual conductors.
Approx. |
|
3 mm (0.1 inch) | Wire |
Up A
Contact | Insert |
Insert the wire until A position and clamp the contacts.
Prepare the individual conductors for clamping. Use MOLEX band tool part number
After clamping the contacts, push them into the proper holes in the accessory connector of this camera until they snap in place.
Up
Wire
Contact
Cautions:
•Shrinking the