COMSPHERE DualFlow Data Service Units

Table C-9

(2 of 2)

Dial Backup Error Messages

Message

Notify NMS 1

Condition

Action

DBM:No Ringing

No

DBM is not getting ringback

Look for line problems. If conditions are

 

 

from the other end.

good and no problem is found, call

 

 

 

telephone company and report the

 

 

 

problem.

 

 

 

 

 

DBM:

No

Call attempt failed for

1.

Check DBM for proper operation by

NotConnected

 

unspecified reasons.

 

running a Device Test.

 

 

 

2.

Check the DBM's configuration options

 

 

 

 

to ensure that DBM is enabled.

 

 

 

3.

If you cannot correct the problem,

 

 

 

 

contact your service representative.

 

 

 

 

 

DBM:ProtoErrnn

No

Protocol error (nn is the error

1.

Check the lines. Line quality has

 

 

number) by the 2-wire Switched

 

degraded. (A call to the central office

 

 

56 DBM.

 

to perform diagnostic tests may be

 

 

 

 

required.)

 

 

 

2.

If the line quality is good, note the

 

 

 

 

protocol error number and whether the

 

 

 

 

DBM was originating or answering a

 

 

 

 

call, then contact your service

 

 

 

 

representative.

 

 

 

 

DBM:

Yes

The rate in the calling and

Check speed configured in both units.

RateMismatch

 

called DBM or modem are not

 

 

 

 

compatible.

 

 

 

 

 

 

 

DBM:SecurityFail

No

Passwords in calling and called

1.

Make sure that both DBMs have

 

 

DBM do not match.

 

compatible security options.

 

 

 

2.

Make sure that both DBMs have the

 

 

 

 

proper password.

 

 

 

 

 

1If Yes, an error message is reported to the NMS if the NMS initiated the dial command.