Unit Configuration

Table 5-3

(3 of 4)

DBM Configuration Options

Call Setup:None

Next None Pswrd Cllbk Alarm Prev

Dial Backup Call Setup. Establishes the security level on call setup attempts. The Password and Callback security selections use a proprietary password exchange to ensure that the DBM does not route line data to the DBM's DTE interface. If security fails, the call is disconnected. These password exchanges only work between 3600 Series DBMs.

None

Ð

No security. Outgoing calls have no security. For incoming calls, if the calling device is not a 3600 Series

 

 

DBM, an answering DBM with Call Setup set to None will automatically switch from Standby to Dial

 

 

Backup mode after the time-out period has expired.

Pswrd

Ð

Intermediate security level. The originating and answering DBMs must exchange valid passwords to

 

 

establish a call.

Cllbk

Ð

Highest security level. The originating and answering DBMs exchange passwords and disconnect; the

 

 

answering DBM calls the originator back with a second exchange of passwords.

Alarm

Ð

Causes a DBM to answer incoming calls only when the DSU reports a Facility Alarm. No security

 

 

checking is performed. This feature is for customers that provide data services to other customers that

 

 

may not have non-3600 Series DBMs.

RxPwd:

Next Chang Prev

Receive Password. The password that the DBM expects to receive from a remote DBM (must be the same as the remote DBM's TxPwd). The maximum password length is 10 characters. The default, *, is a wildcard meaning ªany character string.º When Call Setup is set to None or Alarm, this configuration option will not appear.

Chang Ð Enter up to 10 characters for the receive password. An underscore ( _ ) to the immediate right of the last password character is required for passwords of fewer than 10 characters in length. To make the password invisible to the DCP, enter a comma ( , ) as the first character.

TxPwd:

Next Chang Prev

Transmit Password. The password that the DBM sends to a remote DBM (must be the same as the remote DBM's RxPwd). The maximum password length is 10 characters. The default is a null password. When Call Setup is set to None or Alarm, this configuration option will not appear.

Chang Ð Enter up to 10 characters for the receive password. An underscore ( _ ) to the immediate right of the last password character is required for passwords of fewer than 10 characters in length. To make the password invisible to the DCP, enter a comma ( , ) as the first character.

Dial Test:Disab

Next Enab Disab Prev

Dial Test. When enabled, the DBM periodically checks for a signal or dial tone. If the test fails, the DSU reports a Dial Test Failure alarm in its health and status. A Dial Test occurs once every 60 minutes until a failure occurs. Then, the test repeats every minute until the network recovers.

If enabled, the V.32 DBM periodically tests receipt of dial tone, the 4-wire Switched 56 DBM goes off-hook and checks for receipt of a data mode idle (DMI) signal burst (referred to as winkback detection), and the 2-wire Switched 56 DBM goes off-hook and checks for receipt of a proceed-to-select message from the switch.

Enab

Ð

Enables the Dial Test.

Disab

Ð

Disables the Dial Test.