Device Health and Status Messages

 

 

Message

Condition

 

 

Redun Fan Alarm

Indicates a problem with the fan on the ±48 Vdc Central Office Power Unit.

 

 

Redun Pwr Alarm

Indicates a problem with the power on the ±48 Vdc Central Office Power Unit.

 

 

Subnetwrk Alarm

A major alarm was set Off by one of the devices in your subnetwork. Check the

 

Subnetwork Health and Status report.

 

 

Subtree Truncat

Downstream health and status information has been truncated because it overflowed

 

system limits.

 

 

OutofFrameThresh

For DBMs operating on a single port (rate adaption or nondisruptive), the local DBM

 

has detected a continuous Out-of-Frame condition. The alarm clears when a local DBM

 

synchronizes with a remote DBM.

 

On a point-to-point circuit, if the alarm continues and the local DSU is configured for

 

automatic backup, the local DSU disruptively tests the DDS circuit. If the test fails, the

 

local DSU initiates a DDS Facility Alarm and initiates dial backup.

 

 

nn.n DDS

Indicates the speed (nn.n) of the DSU core when there are no alarms.

 

 

nnn Disable

Transmitter at nnn (DSU or DBM) is disabled. (Go to the Control branch to enable the

 

DSU or DBM.)

 

 

nnn DTR Alarm

The DTR lead at nnn (DSU or DBM) has been Off for more than 30 seconds.

 

 

nnn StreamTerm

Streaming terminal. DTE at nnn (DSU or DBM) has its RTS lead turned ON longer than

 

the predefined time.

 

 