Image 73

COMSPHERE DualFlow Data Service Units

 

 

 

 

Table 5-2

 

 

 

 

(2 of 3)

 

 

 

 

DSU Port Configuration Options

 

 

 

 

LSD Lead: Std

 

 

 

Next

Std

Delay

FrcOn

Prev

 

Line Signal Detect Lead. Controls behavior of the Line Signal Detect lead.

Std

Ð LSD lead goes Off in response to a control mode idle (CMI) signal from the DDS network or DDS failure.

Delay

Ð LSD does not go Off in response to a network alarm condition or CMI. LSD goes Off only after a

 

successful backup connection is established.

FrcOn

Ð Keeps LSD on as long as the DSU has power.

 

 

 

DSR FrcOn: Enab

 

 

Next

Enab

Disab

Prev

 

 

 

 

 

 

Data Set Ready Forced On. Provides the ability to override any other options controlling the Data Set Ready lead.

Enab

Ð

DSR remains ON as long as the device is working, regardless of tests and network alarms.

Disab

Ð

DSR functions as an active lead reflecting various test and alarm conditions and other options.

 

 

 

SystemStat: Enab

 

 

Next

Enab

Disab

Prev

 

 

 

 

 

System Status. Controls the behavior of the DSR lead in response to a No Signal, Out-of-Service, or Out-of-Frame alarm from the network.

Enab

Ð Network alarm turns Off DSR.

 

Disab

Ð Network alarm does not affect DSR.

 

 

 

 

 

DSR on Tst: Enab

 

 

 

Next

Enab

Disab

Prev

 

 

 

Data Set Ready On in Test. Controls the behavior of the DSR lead during testing.

 

Enab

Ð DSR is ON continuously during testing, allowing a DTE that relies on DSR being ON to send test

 

 

messages to the DSU.

 

Disab

Ð DSR is Off during testing.

 

 

 

 

 

Circ Assur:Disab

 

 

 

Next

Enab

Disab

Prev

 

 

 

 

 

 

Circuit Assurance. Controls behavior of the CTS lead in response to a data signal from the network. If CTS Cntrl is set to RTS and RTS Cntrl is set to FrcOn, this configuration option is ignored.

A DDS Facility Alarm condition turns Off the CTS lead, regardless of the Circuit Assurance setting.

Enab

Ð

The DSU will turn Off the CTS lead if the DSU receives control mode idle (CMI) from the network.

Disab

Ð

The DSU is not affected by the receipt of CMI.

 

 

RespondRDL:Disab

 

Next

Enab

Disab

Prev

 

 

 

 

 

Respond to Remote Digital Loopback. Determines whether the DSU responds to a V.54 Remote Loopback request.

Enab

Ð

Performs a Digital Loopback.

Disab

Ð

Ignores the Loopback command.

5-8