Paradyne 3616, 3615 Using the DCP to Set Configuration Options, Editing Configuration Options

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 67
Image 67

COMSPHERE DualFlow Data Service Units

Selection of Activ, Usr1, Usr2, Usr3, SyBC, SyBT, or DiDg from the Load from menu brings a complete set of configuration option into the working buffer. Once loaded, the Edit/Save submenu appears (shown below).

Edit / Save:

SAVE DSU DSUpt

F1 F2 F3

Using the DCP to

Set Configuration Options

Any one of the following 6 configuration option sets can be selected: DSU, DSU Port, DBM, DBM Port, Diagnostic (DBM and General), and Backup. The configuration options can be edited and then saved to the Activ, Usr1, Usr2, or Usr3 storage areas.

In addition, an example is included to illustrate DCP operation.

Editing Configuration Options

To edit or change configuration options:

.Procedure

1.Select Local, or Remot (Remote) and the remote DSU's network address.

2.Select Confg (Configuration branch).

Press the

 

key until Confg appears, then press

 

 

the function key (F1, F2, or F3) directly below Confg.

3.Select Opts (Configuration Options).

4.Select storage area (Activ, Remt, Usr1, etc.) from the Load from screen.

If the unit is a control and you select Remt, enter the network address of the remote DSU.

5.Select the option set (e.g., DSU, DSUpt, DBM, etc.) to be edited.

The first configuration option within that set appears. Page through each configuration option within the set as follows:

a.Press the F1 key to go to the Next configuration option. These configuration options scroll or wrap around (e.g. first, then last; or last, then first).

b.To return to the previous configuration option,

press the key instead of selecting Next. Prev appears over the F1 key.

c.Select Prev by pressing the F1 key.

As you edit configuration options, be aware of the following:

The first line of each configuration option identifies the option and its current setting.

If configuration data has been corrupted, ??? will appear in place of the current value. If this occurs, reset all configuration options, along with the network address. Check the Backup Directory entries, the poll list, and the DSU's local telephone number, as well.

The second line displays all values that are available for selection ± three at a time, one above each function key.

ÐPress the or key to scroll other selections into view.

ÐPress the function key (F1, F2, or F3) directly below a value to select it.

ÐSelect Next to proceed to the next option.

ÐSelect Prev to return to a previous option.

ÐPress the key to return to the Edit/Save submenu or screen, and select the next option set to be edited.

5-2

December 1996

3615-A2-GB20-20

Page 67
Image 67
Paradyne 3616, 3615 manual Using the DCP to Set Configuration Options, Editing Configuration Options