Paradyne 3616, 3615 manual CarrLossDisc Yes Next Yes No Prev, Auto RetrainYes Next Yes No Prev

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 75
Image 75

COMSPHERE DualFlow Data Service Units

Table 5-3

(2 of 4)

DBM Configuration Options

TxClkSource: Int for a control DBM, RXC for a tributary DBM

Next Int RXC Ext Prev

Transmit Clock Source. Source of timing for the DBM. Only appears for a V.32 DBM.

Int

Ð Internal clock source. The local DBM provides the timing. This source is used primarily in point-to-point

 

applications.

RXC

Ð Receive clock source. This source is used primarily in multipoint tributary applications.

Ext

Ð External clock source. This source is used primarily in applications where the connected DTE must

 

provide the timing, such as when a 3616 V.32 DBM with its DBM Primary Core configuration option set to

 

Yes and where timing is received from the digital bridge.

CarrLossDisc: Yes

Next Yes No Prev

Carrier Loss Disconnect. Controls whether the V.32 DBM terminates a call when the receive signal carrier is lost or the signal becomes unacceptable.

Yes

Ð

Call is terminated upon loss of carrier.

No

Ð

For factory testing only. Never set Carrier Loss Disconnect to No. Doing so will cause an off-hook line

 

 

condition, resulting in excessive telephone charges.

Auto Retrain:Yes

Next Yes No Prev

Automatic Retrain. Controls the automatic start of a retrain sequence by the DBM when received signal quality becomes unacceptable. Only appears for a V.32 DBM.

Yes

Ð

Retraining is initiated automatically.

No

Ð

Retraining is not initiated automatically; however, the DBM will respond to a retrain request from a remote

 

 

modem.

Single Rate: No

Next Yes No Prev

Single Rate. Determines whether the DBM will adjust its rate to resolve a rate mismatch with a remote DBM. Single Rate must be set to Yes if rate adaption or non-disruptive diagnostics are enabled. Only appears for a V.32 DBM.

If Rate(Kbps) is set to 2.4, the DBM can only talk to a 2.4 kbps modem, regardless of the Single Rate setting. (Will only train at 2.4 kbps.)

Yes

Ð

The DBM operates only at the rate for which it is configured.

No

Ð

The DBM will adjust its rate downward to correct a mismatch.

AutoAnswer: Enab

Next Enab Disab Prev

Automatic Answer. Controls whether the DBM answers incoming calls.

Enab

Ð

DBM answers incoming calls.

Disab

Ð

DBM does not answer incoming calls.

5-10

December 1996

3615-A2-GB20-20

Page 75
Image 75
Paradyne 3616, 3615 CarrLossDisc Yes Next Yes No Prev, Auto RetrainYes Next Yes No Prev, Single Rate No Next Yes No Prev