Unit Configuration
Table
(3 of 3)
DBM Port Configuration Options
CCN by EL: Disab
Next Enab Disab Prev
Configuration Change Notification by External Leads. Controls using the
Enab | Ð | Change in state of a |
Disab | Ð |
DTR Alarm: Disab
Next Enab Disab Prev
Data Terminal Ready Alarm. Causes the DSU to generate an alarm if DTR is Off for more than 30 seconds. The DCP displays DTR Alarm and reports the alarm to the NMS.
Enab | Ð | If DTR lead turns Off for 30 seconds, the DSU generates an alarm. | ||
Disab | Ð | Regardless how long the DTR lead is Off, no alarm is generated. | ||
| ||||
Async→ Sync: Enab for DiDg, Disab for SyBC and SyBT configurations | ||||
Next | Enab | Disab | Prev | |
|
|
|
|
|
Enab | Ð | Configures the DBM as asynchronous | ||||
Disab | Ð | Configures the DBM as synchronous. | ||||
| ||||||
AsyncBit/Char: 8 for DiDg configuration | ||||||
Next | 6 | 7 | 8 | 9 | 10 | Prev |
|
|
|
|
|
|
|
Asynchronous Bits per Character. Specifies the length of a character, including the parity bit but excluding the start and stop bits. This configuration option only applies to the Dial Diagnostic (DiDg) configuration.
6 to 10 | Ð | Selects the asynchronous bits per character. When Stop Bits is set to 2, 10 will not be displayed. | |
| |||
Stop Bits: 1 for DiDg configuration | |||
Next | 1 | 2 | Prev |
|
|
|
|
Stop Bits. Specifies the number of stop bits in an asynchronous character. This configuration option only applies to the Dial Diagnostic (DiDg) configuration.
1 to 2 | Ð Selects the number of stop bits to be used. When the AsyncBit/Char configuration option is set to 10, 2 | ||
|
| will not be displayed. | |
| |||
Overspeed: 2.3 for DiDg, not applicable for other configurations | |||
Next | 1.0 | 2.3 | Prev |
|
|
|
|
Overspeed. Selects the overspeed range of the
1.0Ð Selects the basic overspeed range. Basic range provides 1.0% overspeed in the DTE or router asynchronous data rate.
2.3Ð Selects the overspeed percentage for extended range. Extended range provides 2.3% overspeed in the DTE or router asynchronous data rate.
December 1996 |