Unit Configuration

Table 5-4

(3 of 3)

DBM Port Configuration Options

CCN by EL: Disab

Next Enab Disab Prev

Configuration Change Notification by External Leads. Controls using the general-purpose output leads to set a CCN event. This configuration option only has an effect if Ext Leads is set to ExtLd.

Enab

Ð

Change in state of a general-purpose lead signals CCN to the NMS.

Disab

Ð

General-purpose lead changes do not set a CCN event.

DTR Alarm: Disab

Next Enab Disab Prev

Data Terminal Ready Alarm. Causes the DSU to generate an alarm if DTR is Off for more than 30 seconds. The DCP displays DTR Alarm and reports the alarm to the NMS.

Enab

Ð

If DTR lead turns Off for 30 seconds, the DSU generates an alarm.

Disab

Ð

Regardless how long the DTR lead is Off, no alarm is generated.

 

AsyncSync: Enab for DiDg, Disab for SyBC and SyBT configurations

Next

Enab

Disab

Prev

 

 

 

 

 

Asynchronous-to-Synchronous Conversion. Sets the DBM port for asynchronous or synchronous operation.

Enab

Ð

Configures the DBM as asynchronous (asynchronous-to-synchronous conversion takes place).

Disab

Ð

Configures the DBM as synchronous.

 

AsyncBit/Char: 8 for DiDg configuration

Next

6

7

8

9

10

Prev

 

 

 

 

 

 

 

Asynchronous Bits per Character. Specifies the length of a character, including the parity bit but excluding the start and stop bits. This configuration option only applies to the Dial Diagnostic (DiDg) configuration.

6 to 10

Ð

Selects the asynchronous bits per character. When Stop Bits is set to 2, 10 will not be displayed.

 

Stop Bits: 1 for DiDg configuration

Next

1

2

Prev

 

 

 

 

Stop Bits. Specifies the number of stop bits in an asynchronous character. This configuration option only applies to the Dial Diagnostic (DiDg) configuration.

1 to 2

Ð Selects the number of stop bits to be used. When the AsyncBit/Char configuration option is set to 10, 2

 

 

will not be displayed.

 

Overspeed: 2.3 for DiDg, not applicable for other configurations

Next

1.0

2.3

Prev

 

 

 

 

Overspeed. Selects the overspeed range of the asynchronous-to-synchronous converter. This configuration option is only displayed when the AsyncSync configuration option is enabled.

1.0Ð Selects the basic overspeed range. Basic range provides 1.0% overspeed in the DTE or router asynchronous data rate.

2.3Ð Selects the overspeed percentage for extended range. Extended range provides 2.3% overspeed in the DTE or router asynchronous data rate.

3615-A2-GB20-20

December 1996

5-15