COMSPHERE DualFlow Data Service Units

Table 5-5

Diagnostic DBM Configuration Options

Diag Type: Disr

Next NonD Disr None Prev

Diagnostic Type. Defines the diagnostic interaction between the control and tributary DBMs in Backup mode. It must be set consistently for all Dualflow DBMs on the same circuit.

NonD

Ð Nondisruptive Diagnostics. An in-band secondary channel transport is derived to carry diagnostics data

 

 

between the control and the tributary DBMs.

Disr

Ð Disruptive Diagnostics. The same (primary) channel that carries user-transmitted data between the

 

 

control and the tributary DBMs also carries diagnostic data. This mode should be selected for

 

 

compatibility with earlier releases that use session-disruptive diagnostics.

None

Ð No diagnostic communications with remote devices; only local diagnostics are allowed.

 

 

 

 

 

2nd Ch(bps): 400

 

 

 

 

Next

100

400

800

1200

1600

Prev

 

 

 

 

 

 

 

In-band Secondary Channel Diagnostic Transport Speed (in bps). Determines the DBM's port speed when NonD (nondisruptive diagnostics) is selected and there is no excess bandwidth available for in-band secondary channel transport operation. (This configuration option only appears when DiagType = NonD.)

The selection entered here allocates DBM port bandwidth to the in-band secondary channel transport. For example, both the DBM port speed and the backup line speed are 9.6 kbps, and the Diagnostic Type entered is NonD and the In-band Secondary Channel Diagnostic Transport Speed entered is 400. The resulting DBM port speed is 9.2 kbps. (Refer to the following list for valid diagnostic speeds.)

If the DBM Rate(Kbps) is equal to

 

Port Speed:

Valid diagnostic speeds are:

1.2

100, 400

2.0

100, 400

2.4

100, 400, 800

4.0

100, 400, 800

4.8

100, 400, 800, 1200, 1600

7.2

100, 400, 800, 1200

8.4

100, 400, 1600

9.6

100, 400, 800, 1200, 1600

12.0

100, 400, 800, 1200

14.4

100, 400, 800, 1200, 1600

16.8

100, 400, 800, 1200

18.0

100, 400, 1200

19.2

100, 400, 800, 1200, 1600

28.8

100, 400, 800

32

100, 400, 800, 1200

38.4

100, 400, 800, 1200, 1600

48

100, 400, 800, 1200, 1600

56

100, 400, 800, 1200

5-16

December 1996

3615-A2-GB20-20

Page 81
Image 81
Paradyne 3616, 3615 manual Diagnostic DBM Configuration Options, Diag Type Disr Next NonD Disr None Prev