Paradyne 3615, 3616 manual Bit Error Rate Test, End-to-End Test Results

Models: 3615 3616

1 135
Download 135 pages 29.39 Kb
Page 56
Image 56

COMSPHERE DualFlow Data Service Units

 

 

 

Table 4-4

 

 

End-to-End Test Results

Results

Reported By 1

 

Information Displayed

Time:

Local and remote DBM

 

Running test timer. (The Clr selection resets the timer to 0:00:00.)

 

 

 

 

Tot Block:

Local and remote DBM

 

Number of blocks completed. (The Clr selection resets the counter to 0.)

 

 

 

 

Rx Blk err:

Local and remote DBM

 

Number of incoming blocks with errors detected, indicating a fault in the

 

 

 

incoming transmission path. (The Clr selection resets the counter to 0.)

 

 

 

 

Tx Blk err:

Local and remote DBM

 

Number of blocks with errors detected at the remote DSU, indicating a

 

 

 

fault in the outgoing transmission path. (The Clr selection resets the

 

 

 

counter to 0.)

 

 

 

 

Rx TimOuts:

Local DBM only

 

Number of blocks that were not received or acknowledged by the

 

 

 

remote DSU or DBM. (The Clr selection resets the counter to 0.)

 

 

 

 

1 Local refers to the test initiator.

 

 

Bit Error Rate Test

The Bit Error Rate Test (BERT) is a session- disruptive test that transmits a 511-bit pattern. It analyzes the network circuit. It can monitor the results by putting the remote DSU or DBM into Digital Loopback and checking the returned pattern for errors, or by simultaneously executing a BERT in the local DSU.

The test continues until aborted from the DCP or NMS.

If nondisruptive diagnostics are in effect (if Diag Type is set to NonD), diagnostic data can be disrupted.

To display the results of the test, press F2 to select Displ. The results are shown in Table 4-5. To clear the results of the test and clear the counters to zero, press F3 to select Clr.

Table 4-5

Bit Error Rate Test Results

Results

Information Displayed

 

 

Time:

Running test timer. (The Clr

 

selection resets the timer to

 

0:00:00.)

 

 

Tot Error:

Running count of bits in

 

error; Max, if the maximum error

 

count has been reached, which

 

is 64000. (The Clr selection

 

resets the counter to 0.)

 

 

Err Secs:

Running count of errored

 

seconds. Errored second is at

 

least one error is detected during

 

a 1-second time period. (The Clr

 

selection resets the counter to

 

0.)

 

 

4-12

December 1996

3615-A2-GB20-20

Page 56
Image 56