COMSPHERE DualFlow Data Service Units
| Table | ||
General Technical Specifications | |||
Specifications |
|
| Criteria |
|
|
|
|
APPROVALS |
|
|
|
FCC Part 15 | Class A digital device | ||
FCC Part 68 | |||
UL |
|
|
|
3615 DualFlow DSU | Listed UL 1950, second edition | ||
3616 DualFlow DSU, | Recognized Component UL 1950, second edition | ||
3000 Series Carrier |
|
|
|
CSA |
|
|
|
Safety |
|
|
|
3615 DualFlow DSU | Certified CSA 22.2, No. | ||
3616 DualFlow DSU, | Certified Component CSA 22.2, No. | ||
3000 Series Carrier |
|
|
|
Emissions | CSA 108.8 ± M1983, Class A digital apparatus | ||
Bell Canada | ªDCTE Specifications,º July 1989, Issue 1 | ||
|
|
|
|
AC POWER REQUIREMENTS |
|
|
|
3615 DualFlow DSU | 24 Vac (CT), 60 HZ ± 3 (0.115 amp, 9.5 watts at 115 Vac) | ||
3616 DualFlow DSU | 24 Vac (CT), 60 Hz +3 (0.080 amp, 8.0 watts at 115 Vac) | ||
3000 Series Carrier (16 DualFlow DSUs, | 90Ð132 Vac, 60 Hz + 3 (1.650 amp, 165 watts at 115 Vac) | ||
plus SDU and fan module) |
|
|
|
|
|
|
|
DTE INTERFACE |
|
|
|
3615 DualFlow DSU |
|
|
|
CCITT V.35 (ISO 2593) | |||
3616 DualFlow DSU with | |||
CCITT V.35 (ISO 2593) | |||
Uses a Rear Connector Plate with two | (A V.35 Interconnect Cable is required to use the V.35 connector. The | ||
cable provides an interface between the DSU's | |||
| and the DTE cable's V.35 connector.) | ||
|
|
|
|
ENVIRONMENT |
|
|
|
Operating Temperature | 32° to 122° F (0° to 50° C) | ||
Storage Temperature | ±4° to 158° F (±20° to 70° C) | ||
Relative Humidity | 5%Ð95% (noncondensing) | ||
Shock and Vibration | Withstands normal shipping and handling | ||
|
|
|
|
HEAT DISSIPATION (MAX.) AT 115 VAC |
|
|
|
3615 DualFlow DSU | 29.00 Btu/hr | ||
3616 DualFlow DSU | 27.30 Btu/hr | ||
3000 Series Carrier (16 DualFlow DSUs | 563.00 Btu/hr | ||
plus SDU and fan module) |
|
|
|
|
| ||
NMS COMPATIBILITY | COMSPHEREr 6700 Series NMS, Release 4.0 or greater | ||
| COMSPHEREr 6800 Series NMS, Release 4.1.5 or greater | ||
|
|
|
|
December 1996 |